Literature DB >> 1811797

Quantitative analysis of the molecular species of monosialogangliosides by continuous-flow fast-atom bombardment mass spectrometry.

S Chen1, G Pieraccini, G Moneti.   

Abstract

Negative-ion continuous-flow fast-atom bombardment mass spectrometry was evaluated as a means for the quantitative analysis of N-acetylneuraminyl-galactosyl-glucosyl-ceramide (NeuAc-GM3) and N-acetylgalactosaminyl-(N-acetylneuraminyl)galactosyl-glucosyl-ceramide (NeuAc-GM2). This study was carried out on a 7070-EQ mass spectrometer (VG Analytical, Manchester, UK) using a home-made continuous-flow fast-atom bombardment probe with a mixture of methanol + water + triethanolamine (70:27:3, v/v/v) as the mobile phase. Utilizing 100 ng of acetyl-lysogalactosyl-N-acetylgalactosaminyl-(N-acetylneuraminyl)g alactosyl-glucosyl-ceramide (acetyl-lysoGM1) as an internal standard, standard curves for NeuAc-GM3 d18:1-16:0, NeuAc-GM3 d18:1-18:0 and Neuac-GM2 d18:1-18:0 were found to be linear over the range 5-250 ng, with associated correlation coefficients of 0.990-0.997. The lower limit of detection was found to be 2.5 ng. Satisfactory results could also be obtained when the calibration curves were derived from the deprotonated molecular ions of a mixture of the NeuAc-GM2 and NeuAc-GM3 classes. Using this approach, quantitative determination of NeuAc-GM3 d18:1-16:0 from rat adrenal gland was performed using N-acetylneuraminic acid assay as a test control. We found 278 +/- 36 ng of this species in 1 mg of tissue (three replicate experiments). The procedure represents a sensitive method for the quantitation of monosialogangliosides and its capability to give molecular species information.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 1811797     DOI: 10.1002/rcm.1290051210

Source DB:  PubMed          Journal:  Rapid Commun Mass Spectrom        ISSN: 0951-4198            Impact factor:   2.419


  2 in total

1.  Matrix-assisted laser desorption ionization time-of-flight mass spectrometry of underivatized and permethylated gangliosides.

Authors:  P Juhasz; C E Costello
Journal:  J Am Soc Mass Spectrom       Date:  1992-11       Impact factor: 3.109

2.  Quantitative analysis of sphingolipids for lipidomics using triple quadrupole and quadrupole linear ion trap mass spectrometers.

Authors:  Rebecca L Shaner; Jeremy C Allegood; Hyejung Park; Elaine Wang; Samuel Kelly; Christopher A Haynes; M Cameron Sullards; Alfred H Merrill
Journal:  J Lipid Res       Date:  2008-11-25       Impact factor: 5.922

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.