Literature DB >> 181167

The His-Purkinje electrocardiogram in man: an initial assessment of its uses and limitations.

E J Berbari, B J Scherlag, N El-Sherif, B Befeler, J M Aranda, R Lazzara.   

Abstract

A methodology is described for noninvasive recording of the electrical activity generated by the His-Purkinje system of man utilizing filtering, high amplification, and signal averaging. A waveform ranging between 1 and 10mu V was observed during the P-R segment. In many individuals, there was temporal overlap between the terminal P wave and the initial portion of the His-Purkinje waveform. In ten patients with long P-R intervals there was a strong correlation (r greater than 0.95) between the H-V time measured by electrode catheter and the duration of the His-Purkinje waveform. In two patients with atrial fibrillation the resultant His-Purkinje waveform was similar in morphology and duration to those observed in the ten patients. In each group H-V time was determined noninvasively and a waveform associated with electrical activation of the major portions of the His-Purkinje system was obtained.

Entities:  

Mesh:

Year:  1976        PMID: 181167     DOI: 10.1161/01.cir.54.2.219

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  5 in total

1.  Digital signal processing system for real-time His-bundle and late potential measurement.

Authors:  M C Kwok; R J Donarski; S W Kelly; M C Fairhurst; D J Taylor; A Manivannen
Journal:  Med Biol Eng Comput       Date:  1992-09       Impact factor: 2.602

2.  Noninvasive recording of His bundle activity with an analog delay device in normal subjects and patients with atrioventricular block.

Authors:  Y Ushiyama; H Okajima; Y Sasaki; M Hasegawa
Journal:  Heart Vessels       Date:  1995       Impact factor: 2.037

3.  Enhancing the reliability in the noninvasive measurement of the his bundle magnetic field using a novel signal averaging methodology.

Authors:  Sengottuvel Senthilnathan; Parasakthi Chandrasekaran; Mariyappa Narayanan; Rajesh Patel; Gireesan Katholil; Madhukar P Janawadkar; Radhakrishnan S Thimmakudy; Muralidharan R Thoddi
Journal:  Ann Noninvasive Electrocardiol       Date:  2012-07       Impact factor: 1.468

4.  Noninvasive beat-to-beat detection of ventricular late potentials.

Authors:  H A al-Nashash; S W Kelly; D J Taylor
Journal:  Med Biol Eng Comput       Date:  1989-01       Impact factor: 2.602

5.  Noninvasive recording of electrical activity in the PR segment in man.

Authors:  R Vincent; N P Stroud; R Jenner; M J English; D J Woollons; D A Chamberlain
Journal:  Br Heart J       Date:  1978-02
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.