Literature DB >> 1810082

A ventilator generating a positive or negative internal compliance.

P Schaller1, A Schulze.   

Abstract

This paper describes technical details of a ventilator for altering the resistive and elastic load placed on respiratory muscles during spontaneous breathing in intubated infants. Positive or negative values for ventilator resistance and/or ventilator compliance can be chosen by superimposing the weighted sum of the flow and/or the volume signal over the input to a pressure controller within the pressure feedback control system of the ventilator. The aim of the study was to compare values of the ventilator's compliance (Cv), as measured with a ventilation mechanics calculator, with those Cv values set by the ventilator's Cv control knob on the front panel. Another aim was to compare measured values of total compliance of a combined ventilator-lung model system (Ct) with the values expected according to theory where 1/Ct = 1/Cv + 1/C1m (Eq. alpha; C1m is the lung model's compliance). The Cv values set on the front panel were nearly identical to those measured (Cvm = 0.97 * Cvs + 0.54) over the whole tested range from -20 to +20 ml/kPa. Similarly, the measured Ct values were almost equal to those expected according to Eq. alpha; the standard deviation of the relative residuals was 2.7% for elastic loading and 12.4% for elastic unloading. We conclude that the ventilator described in this study can effectively provide both elastic loading and elastic unloading of spontaneous breathing, as expected according to theory.

Entities:  

Mesh:

Year:  1991        PMID: 1810082     DOI: 10.3109/03009739109179274

Source DB:  PubMed          Journal:  Ups J Med Sci        ISSN: 0300-9734            Impact factor:   2.384


  4 in total

1.  Adaptive mechanical backup ventilation for preterm infants on respiratory assist modes - a pilot study.

Authors:  Susanne Herber-Jonat; Esther Rieger-Fackeldey; Helmut Hummler; Andreas Schulze
Journal:  Intensive Care Med       Date:  2006-01-24       Impact factor: 17.440

2.  [Preserved spontaneous breathing during partial liquid ventilation. Results of experimental animal studies and their clinical implications].

Authors:  H D Hummler; F Pohlandt; A Schulze
Journal:  Anaesthesist       Date:  2003-12       Impact factor: 1.041

3.  Continuous non-invasive monitoring of tidal volumes by measurement of tidal impedance in neonatal piglets.

Authors:  Florian Kurth; Fabienne Zinnow; Alexandra Prakapenia; Sabrina Dietl; Stefan Winkler; Sascha Ifflaender; Mario Rüdiger; Wolfram Burkhardt
Journal:  PLoS One       Date:  2011-06-07       Impact factor: 3.240

4.  Maintained inspiratory activity during proportional assist ventilation in surfactant-depleted cats early after surfactant instillation: phrenic nerve and pulmonary stretch receptor activity.

Authors:  Richard Sindelar; Esther Rieger-Fackeldey; Anders Jonzon; Peter Schaller; Andreas Schulze; Gunnar Sedin
Journal:  Respir Res       Date:  2006-03-10
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.