Literature DB >> 18094312

Sonographically guided 14-gauge core needle biopsy of breast masses: a review of 2,420 cases with long-term follow-up.

Ji Hyun Youk1, Eun-Kyung Kim, Min Jung Kim, Ki Keun Oh.   

Abstract

OBJECTIVE: The objective of our study was to determine the diagnostic accuracy of sonographically guided core needle biopsy for breast masses by evaluating the outcomes of benign biopsies that had at least a 2-year follow-up.
MATERIALS AND METHODS: In this retrospective study, we included a total of 2,420 lesions from 2,198 women who had undergone sonographically guided 14-gauge core needle biopsy. For evaluating the diagnostic accuracy of this procedure, the pathologic results were reviewed and correlated with rebiopsy or long-term imaging follow-up. Agreement rate, high-risk underestimate rate, ductal carcinoma in situ (DCIS) underestimate rate, and false-negative rate were assessed. The false-negative diagnoses of core needle biopsy were reviewed in detail.
RESULTS: The pathologic results for the core needle biopsies were malignant in 52%, high-risk in 4%, and benign in 44%. The agreement rate was 96% (2,328 of 2,420). The underestimate rate was 29% (36 of 126) for DCIS and 27% (25 of 93) for high-risk (52% for 27 atypical ductal hyperplasia (ADH), 17% for 66 non-ADH). Of 1,071 benign lesions, malignancy was found at rebiopsy in 31 lesions (25 immediate and six delayed false-negative diagnoses), and the false-negative rate was 2.4% (31 of 1,312). The frequency of malignancy in lesions that had rebiopsy because of suspicious imaging findings (19.1%, 26 of 136) was significantly higher than that because of suspicious physical findings or request by patient or physician (0.9%, five of 584).
CONCLUSION: Sonographically guided 14-gauge core needle biopsy is an accurate method for evaluating breast masses. Imaging-pathologic correlation and follow-up of benign biopsy are essential for a successful breast biopsy program.

Entities:  

Mesh:

Year:  2008        PMID: 18094312     DOI: 10.2214/AJR.07.2419

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  29 in total

1.  Recurrent Mastitis after Core Needle Biopsy: Case Report of an Unusual Complication after Core Needle Biopsy of a Phyllodes Tumor.

Authors:  Nikola Kasprowicz; Gerd J Bauerschmitz; Alexandra Schönherr; Stephan E Baldus; Wolfgang Janni; Svjetlana Mohrmann
Journal:  Breast Care (Basel)       Date:  2012-06-22       Impact factor: 2.860

2.  Post-clip placement MRI following second-look US-guided core biopsy for suspicious lesions identified on breast MRI.

Authors:  Sung Eun Song; Nariya Cho; Wonshik Han
Journal:  Eur Radiol       Date:  2017-07-07       Impact factor: 5.315

Review 3.  Comparison of the accuracy of US-guided biopsy of breast masses performed with 14-gauge, 16-gauge and 18-gauge automated cutting needle biopsy devices, and review of the literature.

Authors:  Monica L Huang; Kenneth Hess; Rosalind P Candelaria; Mohammad Eghtedari; Beatriz E Adrada; Nour Sneige; Bruno D Fornage
Journal:  Eur Radiol       Date:  2016-11-14       Impact factor: 5.315

4.  Comparison of the underestimation rate in cases with ductal carcinoma in situ at ultrasound-guided core biopsy: 14-gauge automated core-needle biopsy vs 8- or 11-gauge vacuum-assisted biopsy.

Authors:  Y J Suh; M J Kim; E-K Kim; H J Moon; J Y Kwak; H R Koo; J H Yoon
Journal:  Br J Radiol       Date:  2012-03-14       Impact factor: 3.039

5.  Diagnostic performances of shear wave elastography: which parameter to use in differential diagnosis of solid breast masses?

Authors:  Eun Jung Lee; Hae Kyoung Jung; Kyung Hee Ko; Jong Tae Lee; Jung Hyun Yoon
Journal:  Eur Radiol       Date:  2013-02-20       Impact factor: 5.315

6.  Comparison of Core Needle Biopsy and Excision Specimens for the Accurate Evaluation of Breast Cancer Molecular Markers: a Report of 1003 Cases.

Authors:  Jie Chen; Zu Wang; Qing Lv; Zhenggui Du; Qiuwen Tan; Di Zhang; Bingjun Xiong; Helin Zeng; Juxiang Gou
Journal:  Pathol Oncol Res       Date:  2017-01-10       Impact factor: 3.201

7.  Can concurrent core biopsy and fine needle aspiration biopsy improve the false negative rate of sonographically detectable breast lesions?

Authors:  Yao-Lung Kuo; Tsai-Wang Chang
Journal:  BMC Cancer       Date:  2010-07-16       Impact factor: 4.430

8.  Shear-wave elastography in the diagnosis of solid breast masses: what leads to false-negative or false-positive results?

Authors:  Jung Hyun Yoon; Hae Kyoung Jung; Jong Tae Lee; Kyung Hee Ko
Journal:  Eur Radiol       Date:  2013-05-15       Impact factor: 5.315

Review 9.  Status quo and development trend of breast biopsy technology.

Authors:  Yan-Jun Zhang; Lichun Wei; Jie Li; Yi-Qiong Zheng; Xi-Ru Li
Journal:  Gland Surg       Date:  2013-02

10.  Analysis of false-negative results after US-guided 14-gauge core needle breast biopsy.

Authors:  Ji Hyun Youk; Eun-Kyung Kim; Min Jung Kim; Jin Young Kwak; Eun Ju Son
Journal:  Eur Radiol       Date:  2009-10-28       Impact factor: 5.315