Literature DB >> 18093125

On-site quantification of re-entry ratio of ventilation exhausts in multi-family residential buildings and implications.

J Niu1, T C W Tung.   

Abstract

UNLABELLED: In the worldwide spread of Severe Acute Respiratory Syndrome (SARS) in 2003, cluster of cases occurred in a number of large high-rise residential building blocks, especially in Hong Kong. In this study, we examined one of the most likely virus-spread mechanisms, which is related to the inter-flat or inter-zonal airflow through open-windows caused by buoyancy effects. Dual tracer gases of CO2 and SF6 are employed simultaneously to quantify the amount of the exhaust air coming out of the upper part of the window of a floor that re-enters the lower part of the open-window at the immediate upper floor. It was found that the room air could contain up to 7% of the exhaust air from the lower floor, and this occurs at low wind conditions with a combination of indoor-outdoor temperature difference. The results can well explain the earlier governmental finding that DNA strings of SARS Corono-Virus were detected within the sampled deposits on the window sills of the upper floors of the two index patients' flats. The preliminary and yet alarming conclusion may be that, in high-rise buildings, windows flush with a flat façade can be a major route for the vertical spread of pathogen-containing aerosols. PRACTICAL IMPLICATIONS: The confirmation of the transmission route can have a number of implications to both building design and infectious disease control. With respect to the former, considerations should be given to minimize the inter-flat airflow via windows flush with façade for high-rise buildings with natural ventilation; and with respect to the latter, more targeted and earlier intervention can be implemented in case of any highly infectious disease outbreaks.

Entities:  

Mesh:

Year:  2007        PMID: 18093125     DOI: 10.1111/j.1600-0668.2007.00500.x

Source DB:  PubMed          Journal:  Indoor Air        ISSN: 0905-6947            Impact factor:   5.770


  16 in total

1.  Characteristics of air pollutant dispersion around a high-rise building.

Authors:  Y Zhang; K C S Kwok; X-P Liu; J-L Niu
Journal:  Environ Pollut       Date:  2015-05-16       Impact factor: 8.071

2.  Large eddy simulation of wind-induced interunit dispersion around multistory buildings.

Authors:  Z T Ai; C M Mak
Journal:  Indoor Air       Date:  2015-04-07       Impact factor: 5.770

3.  Analysis of concentration fluctuations in gas dispersion around high-rise building for different incident wind directions.

Authors:  X P Liu; J L Niu; K C S Kwok
Journal:  J Hazard Mater       Date:  2011-07-06       Impact factor: 10.588

4.  Numerical investigation of gaseous pollutant cross-transmission for single-sided natural ventilation driven by buoyancy and wind.

Authors:  Jihong Wang; Qiannan Huo; Tengfei Zhang; Shugang Wang; Francine Battaglia
Journal:  Build Environ       Date:  2020-01-31       Impact factor: 6.456

5.  Wind tunnel tests of inter-flat pollutant transmission characteristics in a rectangular multi-storey residential building, part A: Effect of wind direction.

Authors:  Di Mu; Naiping Gao; Tong Zhu
Journal:  Build Environ       Date:  2016-08-30       Impact factor: 6.456

6.  CFD investigation on the effects of wind and thermal wall-flow on pollutant transmission in a high-rise building.

Authors:  Di Mu; Naiping Gao; Tong Zhu
Journal:  Build Environ       Date:  2018-04-01       Impact factor: 6.456

7.  The airborne transmission of infection between flats in high-rise residential buildings: Particle simulation.

Authors:  N P Gao; J L Niu; M Perino; P Heiselberg
Journal:  Build Environ       Date:  2008-04-06       Impact factor: 6.456

Review 8.  The airborne transmission of infection between flats in high-rise residential buildings: A review.

Authors:  Jiachen Mao; Naiping Gao
Journal:  Build Environ       Date:  2015-09-30       Impact factor: 6.456

9.  The airborne transmission of infection between flats in high-rise residential buildings: Tracer gas simulation.

Authors:  N P Gao; J L Niu; M Perino; P Heiselberg
Journal:  Build Environ       Date:  2007-11-19       Impact factor: 6.456

10.  Gaseous pollutant transmission through windows between vertical floors in a multistory building with natural ventilation.

Authors:  Jihong Wang; Tengfei Zhang; Shugang Wang; Francine Battaglia
Journal:  Energy Build       Date:  2017-08-12       Impact factor: 5.879

View more