Literature DB >> 18092509

Segmental body composition assessment for obese Japanese adults by single-frequency bioelectrical impedance analysis with 8-point contact electrodes.

Susumu Sato1, Shinichi Demura, Tamotsu Kitabayashi, Takanori Noguchi.   

Abstract

This study aimed to determine the accuracy of segmental body composition variables estimated by single-frequency BIA with 8-point contact electrodes (SF-BIA8), compared with dual-energy X-ray absorptiometry (DXA). Subjects were 72 obese Japanese adults (43 males and 29 females) aged 30 to 66 years. Segmental body composition variables (fat free mass: FFM, fat mass: FM, and percent fat mass: %FAT) were measured by these techniques. The correlations between impedance values and FFM measured by DXA were calculated. To examine the consistency in predicted values (SF-BIA8) with the reference (DXA), significant mean differences were tested by t-test and the degree of the difference was assessed by effect size. Correlations between the reference and predicted values were calculated. Additionally, the standard error of estimation (SEE) when estimating the reference from the predictor and the relative value of the SEE to the mean value of the DXA measurement (%SEE) were calculated. Systematic error was examined by Bland-Altman plots. High correlations were found between impedance and FFM measured by SF-BIA8. FFM in the extremities showed high correlations with the reference values, but systematic error was found. SF-BIA8 tended to overestimate FFM in the trunk. The consistencies in %FAT and FM with the reference value are inferior to those for FFM, and SEE values in %FAT and FM were greater than those for FFM. The accuracy of the estimated values in the trunk (FFM, %FAT, and FM) are inferior to those of the total body and extremities.

Entities:  

Mesh:

Year:  2007        PMID: 18092509     DOI: 10.2114/jpa2.26.533

Source DB:  PubMed          Journal:  J Physiol Anthropol        ISSN: 1880-6791            Impact factor:   2.867


  7 in total

1.  Prediction of whole-body and segmental body composition by bioelectrical impedance in morbidly obese subjects.

Authors:  Amanda Jiménez; Wilberto Omaña; Lílliam Flores; María José Coves; Diego Bellido; Verónica Perea; Josep Vidal
Journal:  Obes Surg       Date:  2012-04       Impact factor: 4.129

2.  Reliability and accuracy of segmental bioelectrical impedance analysis for assessing muscle and fat mass in older Europeans: a comparison with dual-energy X-ray absorptiometry.

Authors:  Katharina Mally; Jens Trentmann; Martin Heller; Manuela Dittmar
Journal:  Eur J Appl Physiol       Date:  2011-01-14       Impact factor: 3.078

3.  Rapid weight gain in early infancy is associated with adult body fat percentage in young women.

Authors:  Mari Oyama; Toshiko Saito; Kazutoshi Nakamura
Journal:  Environ Health Prev Med       Date:  2010-05-18       Impact factor: 3.674

4.  Total body composition estimated by standing-posture 8-electrode bioelectrical impedance analysis in male wrestlers.

Authors:  M-F Cheng; Y-Y Chen; T-R Jang; W-L Lin; J Chen; K-C Hsieh
Journal:  Biol Sport       Date:  2015-11-10       Impact factor: 2.806

5.  The Role of Body Adiposity Index in Determining Body Fat Percentage in Colombian Adults with Overweight or Obesity.

Authors:  Robinson Ramírez-Vélez; Jorge Enrique Correa-Bautista; Katherine González-Ruíz; Alejandra Tordecilla-Sanders; Antonio García-Hermoso; Jacqueline Schmidt-RioValle; Emilio González-Jiménez
Journal:  Int J Environ Res Public Health       Date:  2017-09-21       Impact factor: 3.390

6.  Protocol for the WARM Hearts study: examining cardiovascular disease risk in middle-aged and older women - a prospective, observational cohort study.

Authors:  Alexandra V Rose; Kevin F Boreskie; Jacqueline L Hay; Liam Thompson; Rakesh C Arora; Todd A Duhamel
Journal:  BMJ Open       Date:  2021-05-25       Impact factor: 2.692

7.  Percentage of body fat assessment using bioelectrical impedance analysis and dual-energy X-ray absorptiometry in a weight loss program for obese or overweight Chinese adults.

Authors:  Yi-Chun Li; Chia-Ing Li; Wen-Yuan Lin; Chiu-Shong Liu; Hua-Shui Hsu; Cheng-Chun Lee; Fei-Na Chen; Tsai-Chung Li; Cheng-Chieh Lin
Journal:  PLoS One       Date:  2013-04-01       Impact factor: 3.240

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.