Literature DB >> 18091555

Anatomical and functional intrapulmonary shunt in acute respiratory distress syndrome.

Massimo Cressoni1, Pietro Caironi, Federico Polli, Eleonora Carlesso, Davide Chiumello, Paolo Cadringher, Micheal Quintel, Vito Marco Ranieri, Guillermo Bugedo, Luciano Gattinoni.   

Abstract

OBJECTIVES: The lung-protective strategy employs positive end-expiratory pressure to keep open otherwise collapsed lung regions (anatomical recruitment). Improvement in venous admixture with positive end-expiratory pressure indicates functional recruitment to better gas exchange, which is not necessarily related to anatomical recruitment, because of possible global/regional perfusion modifications. Therefore, we aimed to assess the value of venous admixture (functional shunt) in estimating the fraction of nonaerated lung tissue (anatomical shunt compartment) and to describe their relationship.
DESIGN: Retrospective analysis of a previously published study.
SETTING: Intensive care units of four university hospitals. PATIENTS: Fifty-nine patients with acute lung injury/acute respiratory distress syndrome.
INTERVENTIONS: Positive end-expiratory pressure trial at 5 and 15 cm H2O positive end-expiratory pressures.
MEASUREMENTS AND MAIN RESULTS: Anatomical shunt compartment (whole-lung computed tomography scan) and functional shunt (blood gas analysis) were assessed at 5 and 15 cm H2O positive end-expiratory pressures. Apparent perfusion ratio (perfusion per gram of nonaerated tissue/perfusion per gram of total lung tissue) was defined as the ratio of functional shunt to anatomical shunt compartment. Functional shunt was poorly correlated to the anatomical shunt compartment (r2 = .174). The apparent perfusion ratio at 5 cm H2O positive end-expiratory pressure was widely distributed and averaged 1.25 +/- 0.80. The apparent perfusion ratios at 5 and 15 cm H2O positive end-expiratory pressures were highly correlated, with a slope close to identity (y = 1.10.x -0.03, r2 = .759), suggesting unchanged blood flow distribution toward the nonaerated lung tissue, when increasing positive end-expiratory pressure.
CONCLUSIONS: Functional shunt poorly estimates the anatomical shunt compartment, due to the large variability in apparent perfusion ratio. Changes in anatomical shunt compartment with increasing positive end-expiratory pressure, in each individual patient, may be estimated from changes in functional shunt, only if the anatomical-functional shunt relationship at 5 cm H2O positive end-expiratory pressure is known.

Entities:  

Mesh:

Year:  2008        PMID: 18091555     DOI: 10.1097/01.CCM.0000300276.12074.E1

Source DB:  PubMed          Journal:  Crit Care Med        ISSN: 0090-3493            Impact factor:   7.598


  35 in total

1.  Quantitative CT in ARDS: towards a clinical tool?

Authors:  Luciano Gattinoni; Massimo Cressoni
Journal:  Intensive Care Med       Date:  2010-08-06       Impact factor: 17.440

2.  Changes in lung composition and regional perfusion and tissue distribution in patients with ARDS.

Authors:  Jonathan Dakin; Andrew T Jones; David M Hansell; Eric A Hoffman; Timothy W Evans
Journal:  Respirology       Date:  2011-11       Impact factor: 6.424

3.  Will all ARDS patients be receiving mechanical ventilation in 2035? We are not sure.

Authors:  Michael Quintel; Tommaso Tonetti; Luciano Gattinoni
Journal:  Intensive Care Med       Date:  2016-08-11       Impact factor: 17.440

Review 4.  Positive end-expiratory pressure: how to set it at the individual level.

Authors:  Luciano Gattinoni; Francesca Collino; Giorgia Maiolo; Francesca Rapetti; Federica Romitti; Tommaso Tonetti; Francesco Vasques; Michael Quintel
Journal:  Ann Transl Med       Date:  2017-07

5.  Tracheobronchial Slough, a Potential Pathology in Endotracheal Tube Obstruction in Patients With Coronavirus Disease 2019 (COVID-19) in the Intensive Care Setting.

Authors:  Jerry A Rubano; Patrick T Jasinski; Daniel N Rutigliano; Apostolos K Tassiopoulos; James E Davis; Tazeen Beg; Shaji Poovathoor; Sergio D Bergese; Sahar Ahmad; Randeep S Jawa; James A Vosswinkel; Mark A Talamini
Journal:  Ann Surg       Date:  2020-05-20       Impact factor: 12.969

Review 6.  Reducing the burden of acute respiratory distress syndrome: the case for early intervention and the potential role of the emergency department.

Authors:  Brian M Fuller; Nicholas M Mohr; Richard S Hotchkiss; Marin H Kollef
Journal:  Shock       Date:  2014-05       Impact factor: 3.454

7.  Hypervolemia induces and potentiates lung damage after recruitment maneuver in a model of sepsis-induced acute lung injury.

Authors:  Pedro L Silva; Fernanda F Cruz; Livia C Fujisaki; Gisele P Oliveira; Cynthia S Samary; Debora S Ornellas; Tatiana Maron-Gutierrez; Nazareth N Rocha; Regina Goldenberg; Cristiane S N B Garcia; Marcelo M Morales; Vera L Capelozzi; Marcelo Gama de Abreu; Paolo Pelosi; Patricia R M Rocco
Journal:  Crit Care       Date:  2010-06-14       Impact factor: 9.097

8.  Respirator management of sepsis-related respiratory failure.

Authors:  Davide Chiumello; Massimo Cressoni
Journal:  Curr Infect Dis Rep       Date:  2009-09       Impact factor: 3.725

9.  Effect of different seated positions on lung volume and oxygenation in acute respiratory distress syndrome.

Authors:  J Dellamonica; N Lerolle; C Sargentini; S Hubert; G Beduneau; F Di Marco; A Mercat; J L Diehl; J C M Richard; G Bernardin; L Brochard
Journal:  Intensive Care Med       Date:  2013-01-24       Impact factor: 17.440

10.  Electrical impedance tomography compared to positron emission tomography for the measurement of regional lung ventilation: an experimental study.

Authors:  J C Richard; C Pouzot; A Gros; C Tourevieille; D Lebars; F Lavenne; I Frerichs; C Guérin
Journal:  Crit Care       Date:  2009-05-29       Impact factor: 9.097

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.