Literature DB >> 18091057

Megavoltage computed tomography: an emerging tool for image-guided radiotherapy.

Theodore S Hong1, James S Welsh, Mark A Ritter, Paul M Harari, Hazim Jaradat, T Rockwell Mackie, Minesh P Mehta.   

Abstract

BACKGROUND: Helical tomotherapy is a unique approach to image-guided IMRT that combines features of a linear accelerator and a CT scanner. This design allows generation of megavoltage CT (MVCT) images, which among other uses, are used to verify daily setup. In this study, we assessed the image-quality, absorbed radiation doses, and clinical practicality of MVCT from our helical tomotherapy prototype unit.
MATERIALS AND METHODS: Phantom studies were first performed to assess the capabilities of MVCT. Next, MVCT images from human patients prospectively enrolled on institutional review board-approved imaging and treatment protocols were analyzed. MVCT was obtained using a 4-MV beam from the University of Wisconsin helical tomotherapy prototype device. These scans were compared with conventional kilovoltage (kVCT) images from a diagnostic CT scanner.
RESULTS: MVCT images in phantoms demonstrate an ability to detect contrast differences as small as 3%. Small objects, 1.2 to 1.6 mm, were seen with good resolution. In human subjects, MVCT imaging of tumor targets and normal anatomy revealed sufficient detail for patient repositioning. MVCT imaging of metallic objects showed minimal artifact in comparison with kVCT. Patient scans were obtained in about 1 to 5 minutes and resulted in absorbed radiation doses of 1.5 to 3 cGy.
CONCLUSIONS: MVCT is an elegant pretreatment position and setup verification tool. MVCT images of human subjects obtained from the helical tomotherapy unit showed good resolution and contrast. The high-quality three-dimensional information permits its use in day-to-day setup verification. The unique properties of MVCT also provide the potential for primary imaging of anatomic regions near metal prostheses as well as nonmedical applications. Additional investigations are underway to improve image quality, further reduce patient dose, and aid adaptive radiotherapy and dose reconstruction.

Entities:  

Mesh:

Year:  2007        PMID: 18091057     DOI: 10.1097/COC.0b013e3180546770

Source DB:  PubMed          Journal:  Am J Clin Oncol        ISSN: 0277-3732            Impact factor:   2.339


  9 in total

1.  Feasibility and efficacy of helical intensity-modulated radiotherapy for stage III non-small cell lung cancer in comparison with conventionally fractionated 3D-CRT.

Authors:  Jian He; Yan Huang; Yixing Chen; Shiming Shi; Luxi Ye; Yong Hu; Jianying Zhang; Zhaochong Zeng
Journal:  J Thorac Dis       Date:  2016-05       Impact factor: 2.895

2.  Adaptive planning using megavoltage fan-beam CT for radiation therapy with testicular shielding.

Authors:  Poonam Yadav; Kevin Kozak; Ranjini Tolakanahalli; V Ramasubramanian; Bhudatt R Paliwal; James S Welsh; Yi Rong
Journal:  Med Dosim       Date:  2011-09-16       Impact factor: 1.482

3.  Hepatic Failure Caused by Reactivation of YMDD Mutants Occurring during Preemptive Lamivudine Therapy.

Authors:  Chan Ran You; Jeong Won Jang; Jae Ki Choi; Si Hyun Bae; Seung Kew Yoon; Chul Seung Kay; Jong Young Choi
Journal:  Gut Liver       Date:  2010-06-16       Impact factor: 4.519

4.  Helical tomotherapy with concurrent capecitabine for the treatment of inoperable pancreatic cancer.

Authors:  Jeong-Seon Ji; Chi-Wha Han; Jeong-Won Jang; Bo-In Lee; Byung-Wook Kim; Hwang Choi; Ji-Yoon Kim; Young-Nam Kang; Chul-Seung Kay; Ihl-Bohng Choi
Journal:  Radiat Oncol       Date:  2010-06-28       Impact factor: 3.481

5.  Actual anatomical and dosimetric changes of parotid glands in nasopharyngeal carcinoma patients during intensity modulated radiation therapy.

Authors:  Gang Ren; Shou-Ping Xu; Lei Du; Lin-Chun Feng; Bao-Lin Qu; Hai-Xia Liu; Chuan-Bin Xie; Lin Ma
Journal:  Biomed Res Int       Date:  2015-02-22       Impact factor: 3.411

6.  The effect and stability of MVCT images on adaptive TomoTherapy.

Authors:  Poonam Yadav; Ranjini Tolakanahalli; Yi Rong; Bhudatt R Paliwal
Journal:  J Appl Clin Med Phys       Date:  2010-07-02       Impact factor: 2.102

7.  A planning study for palliative spine treatment using StatRT and megavoltage CT simulation.

Authors:  Yi Rong; Poonam Yadav; Bhudatt Paliwal; Lu Shang; James S Welsh
Journal:  J Appl Clin Med Phys       Date:  2010-10-30       Impact factor: 2.102

8.  Recent advances in image-guided radiotherapy for head and neck carcinoma.

Authors:  Sameer K Nath; Daniel R Simpson; Brent S Rose; Ajay P Sandhu
Journal:  J Oncol       Date:  2009-07-29       Impact factor: 4.375

9.  Dosimetric comparison of helical tomotherapy and conventional Linac-based X-knife stereotactic body radiation therapy for primary lung cancer or pulmonary metastases.

Authors:  Shuangshuang Li; Ju Yang; Juan Liu; Shanbao Gao; Baorui Liu; Jing Yan
Journal:  J Thorac Dis       Date:  2018-02       Impact factor: 2.895

  9 in total