Adsorption of radiopharmaceuticals to syringes: setting up a reliable protocol for its assessment.

Tanja Gmeiner Stopar1, Aljaz Socan, Petra Kolenc Peitl.   

Abstract

BACKGROUND: It is well known that various drugs, including radiopharmaceuticals, may adsorb to plastic syringes to different extents. Some reports suggest that adsorption can reach levels of almost 50%. The consequence of adsorption of a radiopharmaceutical and subsequent inadequate dosing can include an inappropriate diagnostic response in patients, an increase in the duration of investigation or treatment, and an increase in cost. AIM: To investigate the extent of adsorption of Tc-succimer to plastic syringes and to set up a reliable protocol for assessment of the extent of retention of drugs to single-use plastic syringes before a new syringe brand and/or radiopharmaceutical are introduced in a nuclear medicine department.
METHODS: Radiopharmaceutical kits from two different manufacturers were compared for retention using syringes from three different producers. To assess the influence of dilution on retention, Tc-succimer preparations were further diluted with sodium chloride solution for injection. Syringes were filled to one-third of their capacity and incubated at room temperature before being emptied into vacuum vials. The radioactivity of the syringes was measured before and after emptying. The extent of retained radioactivity was calculated as a percentage of radioactivity in the syringe before emptying.
RESULTS: Results show that adsorption of Tc-succimer considerably differs between syringe brands. The adsorption of undiluted Tc-succimer in 30 min may exceed 50%.
CONCLUSION: The findings show that measurement of retention in syringes and injection sets should be regarded as an essential aspect of quality assurance before radiopharmaceuticals, syringes and injection sets are used routinely.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 18090223     DOI: 10.1097/MNM.0b013e3282f1b9b7

Source DB:  PubMed          Journal:  Nucl Med Commun        ISSN: 0143-3636            Impact factor:   1.690


  5 in total

1.  The clinical importance of accurate measurement of injected doses for radionuclide myocardial perfusion imaging.

Authors:  Raymond Taillefer
Journal:  J Nucl Cardiol       Date:  2015-08-26       Impact factor: 5.952

2.  Adherence of Tc-99m agents to plastic syringes.

Authors:  Trifon Spyridonidis; Theodoros Skouras; Dimitris J Apostolopoulos
Journal:  J Nucl Cardiol       Date:  2016-09-07       Impact factor: 5.952

3.  Effects of Time and Storage Conditions on the Chemical and Microbiologic Stability of Diluted Buprenorphine for Injection.

Authors:  Johnathan M DenHerder; Ralph L Reed; Jennifer L Sargent; Gerd Bobe; Jan F Stevens; Helen E Diggs
Journal:  J Am Assoc Lab Anim Sci       Date:  2017-07-01       Impact factor: 1.232

4.  Adherence of Tc-99 Sestamibi to Plastic Syringes Could Complicate Efforts in Dose Reduction in MPI SPECT.

Authors:  Sean N Reynolds; Janusz Kikut
Journal:  J Nucl Cardiol       Date:  2015-08-26       Impact factor: 5.952

5.  Unpredictable Nanoparticle Retention in Commonly Used Plastic Syringes Introduces Dosage Uncertainties That May Compromise the Accuracy of Nanomedicine and Nanotoxicology Studies.

Authors:  Uwe Holzwarth; Unai Cossío; Jordi Llop; Wolfgang G Kreyling
Journal:  Front Pharmacol       Date:  2019-11-06       Impact factor: 5.810