Literature DB >> 18087428

Velocity-estimation accuracy and frame-rate limitations in color Doppler optical coherence tomography.

M D Kulkarni1, T G van Leeuwen, S Yazdanfar, J A Izatt.   

Abstract

Color Doppler optical coherence tomography (CDOCT) is a recent innovation that allows spatially localized flow-velocity mapping simultaneously with microstructural imaging. We present a theoretical model for velocity-image formation in CDOCT. The proportionality between the heterodyne detector current Doppler power spectrum in CDOCT and the optical source power spectrum is established. We show that stochastic modifications of the Doppler spectrum by fluctuating scatterer distributions in the flow field give rise to unavoidable velocity-estimation inaccuracies as well as to a fundamental trade-off between image-acquisition rate and velocity precision. Novel algorithms that permit high-fidelity depth-resolved measurements of velocities in turbid media are also reported.

Entities:  

Year:  1998        PMID: 18087428     DOI: 10.1364/ol.23.001057

Source DB:  PubMed          Journal:  Opt Lett        ISSN: 0146-9592            Impact factor:   3.776


  6 in total

1.  Structural and functional imaging of 3D microfluidic mixers using optical coherence tomography.

Authors:  Chuanwu Xi; Daniel L Marks; Devang S Parikh; Lutgarde Raskin; Stephen A Boppart
Journal:  Proc Natl Acad Sci U S A       Date:  2004-05-10       Impact factor: 11.205

2.  Frequency tracking in optical Doppler tomography using an adaptive notch filter.

Authors:  Yueli Chen; Peter Willett; Quing Zhu
Journal:  J Biomed Opt       Date:  2007 Jan-Feb       Impact factor: 3.170

3.  Cancellation of coherent artifacts in optical coherence tomography imaging.

Authors:  D Piao; Q Zhu; N K Dutta; S Yan; L L Otis
Journal:  Appl Opt       Date:  2001-10-01       Impact factor: 1.980

4.  Doppler variance imaging for three-dimensional retina and choroid angiography.

Authors:  Lingfeng Yu; Zhongping Chen
Journal:  J Biomed Opt       Date:  2010 Jan-Feb       Impact factor: 3.170

5.  Twenty-five years of optical coherence tomography: the paradigm shift in sensitivity and speed provided by Fourier domain OCT [Invited].

Authors:  Johannes F de Boer; Rainer Leitgeb; Maciej Wojtkowski
Journal:  Biomed Opt Express       Date:  2017-06-15       Impact factor: 3.732

Review 6.  Doppler optical coherence tomography.

Authors:  Rainer A Leitgeb; René M Werkmeister; Cedric Blatter; Leopold Schmetterer
Journal:  Prog Retin Eye Res       Date:  2014-04-03       Impact factor: 21.198

  6 in total