Literature DB >> 18086067

Airtraq vs standard laryngoscopy by student paramedics and experienced prehospital laryngoscopists managing a model of difficult intubation.

M Woollard1, D Lighton, W Mannion, J Watt, C McCrea, I Johns, L Hamilton, P O'Meara, C Cotton, M Smyth.   

Abstract

Two consecutive, randomised, cross-over trials compared intubation success rates in third-year paramedic students and experienced prehospital practitioners using the Airtraq or a Macintosh laryngoscope with flexible stylet in a manikin model of a Cormack and Lehane grade III/IV laryngoscopic view. First-time intubation rates for the Macintosh and Airtraq for students were 0/23 (0%) vs 10/23 (44%) (44% difference, 95% CI 26-63%, p < 0.001) and for experienced laryngoscopists were 14/56 (25%) vs 47/56 (84%) (59% difference, 95% CI 42-72%, p < 0.0001), respectively. First-time oesophageal intubation rates for students were 15/23 (65%) vs 3/23 (13%) (-52% difference, 95% CI -25 to -72%, p < 0.001) and for experienced practitioners 9/56 (16%) vs 0/56 (0%) (-16% difference, 95% CI -9 to -28%, p = 0.0014). Student paramedics and experienced prehospital laryngoscopists managing a manikin model of a grade III/IV view had increased first-time intubation rates and had lower rates of oesophageal intubation with the Airtraq compared with a standard laryngoscope.

Entities:  

Mesh:

Year:  2008        PMID: 18086067     DOI: 10.1111/j.1365-2044.2007.05263.x

Source DB:  PubMed          Journal:  Anaesthesia        ISSN: 0003-2409            Impact factor:   6.955


  18 in total

Review 1.  [Indirect laryngoscopy : Alternatives to securing the airway].

Authors:  R R Noppens; C Werner; T Piepho
Journal:  Anaesthesist       Date:  2010-02       Impact factor: 1.041

2.  The learning curve for laryngoscopy: Airtraq versus Macintosh laryngoscopes.

Authors:  Marco Baciarello; Michele Zasa; Maria Elena Manferdini; Michela Tosi; Marco Berti; Guido Fanelli
Journal:  J Anesth       Date:  2012-02-21       Impact factor: 2.078

3.  Advances in laryngoscopy: rigid indirect laryngoscopy.

Authors:  Deanne R Cheyne; Patrick Doyle
Journal:  F1000 Med Rep       Date:  2010-08-19

4.  Is the Airtraq optical laryngoscope effective in tracheal intubation by novice personnel?

Authors:  Sang-Jin Park; Won Ki Lee; Deok Hee Lee
Journal:  Korean J Anesthesiol       Date:  2010-07-21

5.  A comparison of 4 airway devices on cervical spine alignment in cadaver models of global ligamentous instability at c1-2.

Authors:  Adam L Wendling; Patrick J Tighe; Bryan P Conrad; Tezcan Ozrazgat Baslanti; Marybeth Horodyski; Glenn R Rechtine
Journal:  Anesth Analg       Date:  2013-01-25       Impact factor: 5.108

6.  Face-to-face tracheal intubation in adult patients: a comparison of the Airtraq™, Glidescope™ and Fastrach™ devices.

Authors:  Zehra Ipek Arslan; Volkan Alparslan; Pınar Ozdal; Kamil Toker; Mine Solak
Journal:  J Anesth       Date:  2015-07-29       Impact factor: 2.078

7.  Airtraq, LMA CTrach and Macintosh Laryngoscopes in Tracheal Intubation Training: A Randomized Comparative Manikin Study.

Authors:  Ayten Saraçoğlu; Didem Dal; Ömer Baygın; Fevzi Yılmaz Göğüş
Journal:  Turk J Anaesthesiol Reanim       Date:  2016-04-01

8.  Comparison of the Laryngeal View during Tracheal Intubation Using Airtraq and Macintosh Laryngoscopes by Unskillful Anesthesiology Residents: A Clinical Study.

Authors:  Carlos Ferrando; Gerardo Aguilar; F Javier Belda
Journal:  Anesthesiol Res Pract       Date:  2011-11-17

9.  Prevention of tooth and gum damage: novel application of airtraq laryngoscope.

Authors:  Mahdi Najafi
Journal:  J Tehran Heart Cent       Date:  2011-11-30

10.  Comparison of the Airtraq and Truview laryngoscopes to the Macintosh laryngoscope for use by Advanced Paramedics in easy and simulated difficult intubation in manikins.

Authors:  Sajid Nasim; Chrisen H Maharaj; Ihsan Butt; Muhammad A Malik; John O' Donnell; Brendan D Higgins; Brian H Harte; John G Laffey
Journal:  BMC Emerg Med       Date:  2009-02-13
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.