Effects of biocidal treatments to inhibit the growth of legionellae and other microorganisms in cooling towers.

H Yamamoto1, T Ezaki, M Ikedo, E Yabuuchi.   

Abstract

The effects of biocidal treatments for cooling towers were examined through the use of chemicals and ultraviolet irradiation to inhibit the growth of legionellae and other microorganisms. In the water of cooling towers without continuous biocidal treatments, heterotrophic bacteria and bacterivorous protozoan first appeared, and then legionellae increased up to 10(4) CFU/100 ml. When a UV sterilizer was connected to the cooling tower, the legionellae count was 1/10 or 1/100 of that in the nontreated tower water. In the water of towers supplemented continuously with the biocidal chemicals, legionellae were not found during a 4-month period. The biocidal treatments tested were proved to suppress the increase of legionellae in cooling-tower water, and thus are useful in preventing the outbreak of legionellosis due to inhalation of contaminated aerosol from the cooling tower system.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 1808473     DOI: 10.1111/j.1348-0421.1991.tb01612.x

Source DB:  PubMed          Journal:  Microbiol Immunol        ISSN: 0385-5600            Impact factor:   1.955


  5 in total

1.  Factors stimulating propagation of legionellae in cooling tower water.

Authors:  H Yamamoto; M Sugiura; S Kusunoki; T Ezaki; M Ikedo; E Yabuuchi
Journal:  Appl Environ Microbiol       Date:  1992-04       Impact factor: 4.792

Review 2.  Amoebae as training grounds for intracellular bacterial pathogens.

Authors:  Maëlle Molmeret; Matthias Horn; Michael Wagner; Marina Santic; Yousef Abu Kwaik
Journal:  Appl Environ Microbiol       Date:  2005-01       Impact factor: 4.792

3.  Efficacy of Colloidal Silver-Hydrogen Peroxide and 2-Bromo-2-nitroporopane-1,3-diol Compounds Against Different Serogroups of Legionella pneumophila Strains.

Authors:  N O Sanli-Yurudu; A Kimiran-Erdem; E O Arslan-Aydogdu; Z Zeybek; S Gurun
Journal:  Indian J Microbiol       Date:  2011-06-29       Impact factor: 2.461

4.  Field trial of biocides for control of Legionella in cooling towers.

Authors:  R H Bentham; C R Broadbent
Journal:  Curr Microbiol       Date:  1995-03       Impact factor: 2.188

5.  Industrial Cooling Tower Disinfection Treatment to Prevent Legionella spp.

Authors:  Matteo Iervolino; Benedetta Mancini; Sandra Cristino
Journal:  Int J Environ Res Public Health       Date:  2017-09-26       Impact factor: 3.390