Literature DB >> 18083480

Successful airway management of a patient with a known difficult airway with the Direct Coupler Interface Video Laryngoscope.

Carin A Hagberg1, Christiane C Vogt-Harenkamp, Dawn G Iannucci.   

Abstract

We present the case of a patient who first presented with unexpected difficult laryngoscopy and intubation after induction of general anesthesia. After multiple failed attempts using direct laryngoscopy, tracheal intubation was successfully performed with the Intubating Laryngeal Mask Airway. He returned to the operating room 5 days later for another surgical procedure, and intubation was performed with the Direct Coupler Interface Video Laryngoscope on the first attempt by the same anesthesiologist.

Entities:  

Mesh:

Year:  2007        PMID: 18083480     DOI: 10.1016/j.jclinane.2007.04.009

Source DB:  PubMed          Journal:  J Clin Anesth        ISSN: 0952-8180            Impact factor:   9.452


  1 in total

1.  Comparison of GlideScope video laryngoscopy and Macintosh laryngoscope in ear-nose and throat surgery.

Authors:  G Misirlioglu; O Sen
Journal:  Ir J Med Sci       Date:  2016-01-05       Impact factor: 1.568