Literature DB >> 18080877

Development of a lateral flow assay for rapid detection of bovine antibody to Anaplasma marginale.

K Nielsen1, W L Yu, L Kelly, R Bermudez, T Renteria, A Dajer, E Gutierrez, J Williams, J Algire, S Torioni de Eschaide.   

Abstract

A rapid lateral flow assay for detection of bovine antibody to Anaplasma marginale was developed. The assay used a recombinant peptide of major surface protein 5 as the antigen and a monoclonal antibody specific for bovine IgG(1) conjugated with colloidal gold beads for detection. Serum and anticoagulated blood samples were obtained from cattle in an area where anaplasmosis was endemic. The samples were selected based on positive identification of the organism in blood smears. The unclotted blood samples were used for PCR determination of the presence of A. marginale while the sera were tested by a commercial competitive enzyme immunoassay (CELISA) and by the lateral flow assay (LFA). Similar samples, collected at a Canadian sales barn, were tested by the CELISA and LFA and 10% were tested by PCR for the presence of A. marginale nucleic acid. In addition, stored serum samples from a second endemic area were tested by CELISA and LFA. Of the 114 smear positive samples, all were positive by CELISA and LFA. All samples were also positive by PCR. Samples from Canadian sources (n=524) were negative in the CELISA but 11 sera gave false positive reactions in the LFA. All samples tested were PCR negative. Of 113 samples from herds with anaplasmosis, 53 were positive in the CELISA and 50 were LFA positive.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18080877     DOI: 10.1080/15321810701734693

Source DB:  PubMed          Journal:  J Immunoassay Immunochem        ISSN: 1532-1819


  5 in total

1.  Normalizing the Optical Signal Enables Robust Assays with Lateral Flow Biosensors.

Authors:  Jin-Ho Park; Eung-Kyu Park; Young Kwan Cho; Ik-Soo Shin; Hakho Lee
Journal:  ACS Omega       Date:  2022-05-19

2.  Assessing the Immunochromatographic Test Strip for Serological Detection of Bovine Babesiosis in Uganda.

Authors:  Dickson Stuart Tayebwa; Amany Magdy Beshbishy; Gaber El-Saber Batiha; Mariam Komugisha; Byaruhanga Joseph; Patrick Vudriko; Ramadan Yahia; Luay Alkazmi; Helal F Hetta; Naoaki Yokoyama; Ikuo Igarashi
Journal:  Microorganisms       Date:  2020-07-24

Review 3.  Biosensor Technologies in Medicine: from Detection of Biochemical Markers to Research into Molecular Targets (Review).

Authors:  B G Andryukov; I N Lyapun; E V Matosova; L M Somova
Journal:  Sovrem Tekhnologii Med       Date:  2020-12-28

Review 4.  Lateral flow assays.

Authors:  Katarzyna M Koczula; Andrea Gallotta
Journal:  Essays Biochem       Date:  2016-06-30       Impact factor: 8.000

5.  In vitro validation of the tear matrix metalloproteinase 9 in-situ immunoassay.

Authors:  Seung Pil Bang; Myeong Jin Son; Harim Kim; You Hyun Lee; Jong Hwa Jun
Journal:  Sci Rep       Date:  2020-09-15       Impact factor: 4.379

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.