Determination of myocardial energetic output for cardiac rhythm pacing.

Dalibor Herman1, Svetlana Prevorovská, Frantisek Marsík.   

Abstract

This research is aimed to the determination of the changes in the cardiac energetic output for three different modes of cardiac rhythm pacing. The clinical investigation of thirteen patients with the permanent dual-chamber pacemaker implantation was carried out. The patients were taken to echocardiography examination conducted by way of three pacing modes (AAI, VVI and DDD). The myocardial energetic parameters-the stroke work index (SWI) and the myocardial oxygen consumption (MVO2) are not directly measurable, however, their values can be determined using the numerical model of the human cardiovascular system. The 24-segment hemodynamical model (pulsating type) of the human cardiovascular system was used for the numerical simulation of the changes of myocardial workload for cardiac rhythm pacing. The model was fitted by well-measurable parameters for each patient. The calculated parameters were compared using the two-tailed Student's test. The differences of SWI and MVO2 between the modes AAI and VVI and the modes DDD and VVI are statistically significant (P<0.05). On the other hand, the hemodynamic effects for the stimulation modes DDD and AAI are almost identical, i.e. the differences are statistically insignificant (P>0.05).

Entities:  

Mesh:

Year:  2007        PMID: 18080208      PMCID: PMC2137944          DOI: 10.1007/s10558-007-9039-3

Source DB:  PubMed          Journal:  Cardiovasc Eng        ISSN: 1567-8822


  19 in total

1.  Effects of physiologic pacing versus ventricular pacing on the risk of stroke and death due to cardiovascular causes. Canadian Trial of Physiologic Pacing Investigators.

Authors:  S J Connolly; C R Kerr; M Gent; R S Roberts; S Yusuf; A M Gillis; M H Sami; M Talajic; A S Tang; G J Klein; C Lau; D M Newman
Journal:  N Engl J Med       Date:  2000-05-11       Impact factor: 91.245

2.  ACC/AHA/NASPE 2002 guideline update for implantation of cardiac pacemakers and antiarrhythmia devices: summary article: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (ACC/AHA/NASPE Committee to Update the 1998 Pacemaker Guidelines).

Authors:  Gabriel Gregoratos; Jonathan Abrams; Andrew E Epstein; Roger A Freedman; David L Hayes; Mark A Hlatky; Richard E Kerber; Gerald V Naccarelli; Mark H Schoenfeld; Michael J Silka; Stephen L Winters; Raymond J Gibbons; Elliott M Antman; Joseph S Alpert; Gabriel Gregoratos; Loren F Hiratzka; David P Faxon; Alice K Jacobs; Valentin Fuster; Sidney C Smith
Journal:  Circulation       Date:  2002-10-15       Impact factor: 29.690

3.  Long-term clinical performance of AAI pacing in patients with sick sinus syndrome: a comparison with dual-chamber pacing.

Authors:  Hiroshi Masumoto; Yuichi Ueda; Rinya Kato; Akihiko Usui; Takashi Maseki; Yasushi Takagi; Masato Usui
Journal:  Europace       Date:  2004-09       Impact factor: 5.214

4.  Electromechanics of paced left ventricle simulated by straightforward mathematical model: comparison with experiments.

Authors:  R C P Kerckhoffs; O P Faris; P H M Bovendeerd; F W Prinzen; K Smits; E R McVeigh; T Arts
Journal:  Am J Physiol Heart Circ Physiol       Date:  2005-06-17       Impact factor: 4.733

5.  Reconstruction of the action potential of ventricular myocardial fibres.

Authors:  G W Beeler; H Reuter
Journal:  J Physiol       Date:  1977-06       Impact factor: 5.182

6.  Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction.

Authors:  Arthur J Moss; Wojciech Zareba; W Jackson Hall; Helmut Klein; David J Wilber; David S Cannom; James P Daubert; Steven L Higgins; Mary W Brown; Mark L Andrews
Journal:  N Engl J Med       Date:  2002-03-19       Impact factor: 91.245

7.  Pulsed Doppler echocardiographic determination of stroke volume and cardiac output: clinical validation of two new methods using the apical window.

Authors:  J F Lewis; L C Kuo; J G Nelson; M C Limacher; M A Quinones
Journal:  Circulation       Date:  1984-09       Impact factor: 29.690

8.  Noninvasive Doppler determination of cardiac output in man. Clinical validation.

Authors:  L L Huntsman; D K Stewart; S R Barnes; S B Franklin; J S Colocousis; E A Hessel
Journal:  Circulation       Date:  1983-03       Impact factor: 29.690

9.  Dual-chamber pacing or ventricular backup pacing in patients with an implantable defibrillator: the Dual Chamber and VVI Implantable Defibrillator (DAVID) Trial.

Authors:  Bruce L Wilkoff; James R Cook; Andrew E Epstein; H Leon Greene; Alfred P Hallstrom; Henry Hsia; Steven P Kutalek; Arjun Sharma
Journal:  JAMA       Date:  2002-12-25       Impact factor: 56.272

10.  Ventricular pacing or dual-chamber pacing for sinus-node dysfunction.

Authors:  Gervasio A Lamas; Kerry L Lee; Michael O Sweeney; Russell Silverman; Angel Leon; Raymond Yee; Roger A Marinchak; Greg Flaker; Eleanor Schron; E John Orav; Anne S Hellkamp; Stephen Greer; John McAnulty; Kenneth Ellenbogen; Frederick Ehlert; Roger A Freedman; N A Mark Estes; Arnold Greenspon; Lee Goldman
Journal:  N Engl J Med       Date:  2002-06-13       Impact factor: 91.245

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.