Literature DB >> 18079840

Optimal interferometer designs for optical coherence tomography.

A M Rollins, J A Izatt.   

Abstract

We introduce a family of power-conserving fiber-optic interferometer designs for low-coherence reflectometry that use optical circulators, unbalanced couplers, and (or) balanced heterodyne detection. Simple design equations for optimization of the signal-to-noise ratio of the interferometers are expressed in terms of relevant signal and noise sources and measurable system parameters. We use the equations to evaluate the expected performance of the new configurations compared with that of the standard Michelson interferometer that is commonly used in optical coherence tomography (OCT) systems. The analysis indicates that improved sensitivity is expected for all the new interferometer designs, compared with the sensitivity of the standard OCT interferometer, under high-speed imaging conditions.

Year:  1999        PMID: 18079840     DOI: 10.1364/ol.24.001484

Source DB:  PubMed          Journal:  Opt Lett        ISSN: 0146-9592            Impact factor:   3.776


  29 in total

1.  Optimization of an angled fiber probe for common-path optical coherence tomography.

Authors:  Xuan Liu; Jin U Kang
Journal:  Opt Lett       Date:  2013-08-01       Impact factor: 3.776

2.  Multi-MHz retinal OCT.

Authors:  Thomas Klein; Wolfgang Wieser; Lukas Reznicek; Aljoscha Neubauer; Anselm Kampik; Robert Huber
Journal:  Biomed Opt Express       Date:  2013-08-30       Impact factor: 3.732

3.  Combined Raman spectroscopy and optical coherence tomography device for tissue characterization.

Authors:  Chetan A Patil; Nienke Bosschaart; Matthew D Keller; Ton G van Leeuwen; Anita Mahadevan-Jansen
Journal:  Opt Lett       Date:  2008-05-15       Impact factor: 3.776

4.  Ultrasound-enhanced optical coherence tomography: improved penetration and resolution.

Authors:  Chuanyong Huang; Bin Liu; Mark E Brezinski
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2008-04       Impact factor: 2.129

5.  Photonic integrated Mach-Zehnder interferometer with an on-chip reference arm for optical coherence tomography.

Authors:  Günay Yurtsever; Boris Považay; Aneesh Alex; Behrooz Zabihian; Wolfgang Drexler; Roel Baets
Journal:  Biomed Opt Express       Date:  2014-03-03       Impact factor: 3.732

6.  Megahertz streak-mode Fourier domain optical coherence tomography.

Authors:  Rui Wang; Julie X Yun; Xiaocong Yuan; Richard Goodwin; Roger R Markwald; Bruce Z Gao
Journal:  J Biomed Opt       Date:  2011-06       Impact factor: 3.170

7.  Miniature forward-viewing common-path OCT probe for imaging the renal pelvis.

Authors:  Xiaoyong Fu; Dhruti Patel; Hui Zhu; Gregory MacLennan; Yves T Wang; Michael W Jenkins; Andrew M Rollins
Journal:  Biomed Opt Express       Date:  2015-03-06       Impact factor: 3.732

8.  Noninvasive in vivo imaging reveals differences between tectorial membrane and basilar membrane traveling waves in the mouse cochlea.

Authors:  Hee Yoon Lee; Patrick D Raphael; Jesung Park; Audrey K Ellerbee; Brian E Applegate; John S Oghalai
Journal:  Proc Natl Acad Sci U S A       Date:  2015-03-03       Impact factor: 11.205

9.  Intravascular optical coherence tomography [Invited].

Authors:  Brett E Bouma; Martin Villiger; Kenichiro Otsuka; Wang-Yuhl Oh
Journal:  Biomed Opt Express       Date:  2017-04-26       Impact factor: 3.732

Review 10.  Optical coherence tomography: fundamental principles, instrumental designs and biomedical applications.

Authors:  Dan P Popescu; Lin-P'ing Choo-Smith; Costel Flueraru; Youxin Mao; Shoude Chang; John Disano; Sherif Sherif; Michael G Sowa
Journal:  Biophys Rev       Date:  2011-08-06
View more