Literature DB >> 18078307

Using forward calculations of the magnetic field perturbation due to a realistic vascular model to explore the BOLD effect.

José P Marques1, R W Bowtell.   

Abstract

This paper assesses the reliability of the infinite cylinder model used previously in the literature to simulate blood oxygenation level dependent (BOLD) signal changes. A three-dimensional finite element method was applied to a realistic model of the cortical vasculature, and the results compared with those generated from a simple model of the vasculature as a set of independent, randomly oriented, infinite cylinders. The realistic model is based on scanning electron microscopy measurements of the terminal vascular bed in the superficial cortex of the rat. Good agreement is found between the two models with regard to the extravascular R(2)* and R(2) dependence on the cerebral blood volume and blood oxygenation fraction. Using the realistic model, it is also possible to gain further understanding of the relative importance of intravascular and extravascular BOLD contrast. A simple parameterisation of the dependence of the relaxation rates on relative cerebral blood volume and blood-tissue susceptibility difference was carried out, allowing discussion of the variation in the form of the haemodynamic response with field strength.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18078307     DOI: 10.1002/nbm.1224

Source DB:  PubMed          Journal:  NMR Biomed        ISSN: 0952-3480            Impact factor:   4.044


  13 in total

1.  High-field MRI of brain iron.

Authors:  Jozef H Duyn
Journal:  Methods Mol Biol       Date:  2011

Review 2.  Transverse NMR relaxation in biological tissues.

Authors:  Valerij G Kiselev; Dmitry S Novikov
Journal:  Neuroimage       Date:  2018-06-07       Impact factor: 6.556

3.  Cortical depth-dependent temporal dynamics of the BOLD response in the human brain.

Authors:  Jeroen C W Siero; Natalia Petridou; Hans Hoogduin; Peter R Luijten; Nick F Ramsey
Journal:  J Cereb Blood Flow Metab       Date:  2011-04-20       Impact factor: 6.200

Review 4.  Study of brain anatomy with high-field MRI: recent progress.

Authors:  Jozef H Duyn
Journal:  Magn Reson Imaging       Date:  2010-04-13       Impact factor: 2.546

5.  Quantitative phenomenological model of the BOLD contrast mechanism.

Authors:  John D Dickson; Tom W J Ash; Guy B Williams; Alexander L Sukstanskii; Richard E Ansorge; Dmitriy A Yablonskiy
Journal:  J Magn Reson       Date:  2011-06-13       Impact factor: 2.229

6.  A computational multiresolution BOLD fMRI model.

Authors:  Zikuan Chen; Vince Calhoun
Journal:  IEEE Trans Biomed Eng       Date:  2011-06-07       Impact factor: 4.538

7.  Effect of surrounding vasculature on intravoxel BOLD signal.

Authors:  Zikuan Chen; Arvind Caprihan; Vince Calhoun
Journal:  Med Phys       Date:  2010-04       Impact factor: 4.071

8.  Volumetric BOLD fMRI simulation: from neurovascular coupling to multivoxel imaging.

Authors:  Zikuan Chen; Vince Calhoun
Journal:  BMC Med Imaging       Date:  2012-04-23       Impact factor: 1.930

9.  Effect of object orientation angle on t2* image and reconstructed magnetic susceptibility: numerical simulations.

Authors:  Zikuan Chen; Vince Calhoun
Journal:  Magn Reson Insights       Date:  2013-02-28

10.  Blood oxygenation level-dependent functional MRI signal turbulence caused by ultrahigh spatial resolution: numerical simulation and theoretical explanation.

Authors:  Zikuan Chen; Zeyuan Chen; Vince Calhoun
Journal:  NMR Biomed       Date:  2012-08-28       Impact factor: 4.044

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.