Literature DB >> 18075882

Cleaning efficacy of high-efficiency particulate air-filtered vacuuming and "dry steam" cleaning on carpet.

Lih-Ming Yiin1, Chang Ho Yu, Peter Ashley, George Rhoads.   

Abstract

Previous studies for lead exposure reduction have indicated the difficulty in reducing surface contamination of carpets with the use of regular vacuum cleaners. To find a solution, a household vacuum cleaner equipped with a high-efficiency particulate air (HEPA) filter and a dust finder indicator, and a "dry steam" cleaner previously reported effective in reducing dust mite allergens in carpets and mattresses were tested for effectiveness in reducing lead dust in carpets. Fifty homes of lead-exposed children were tested in New Jersey. A selected carpet in the living area of each home was tested with two interventions: half was cleaned by HEPA vacuuming twice (VAC-VAC) and the other half by dry steaming between the two HEPA vacuumings (VAC-DSC-VAC). Wipe and vacuum samples, representing surface dust and total dust collections, respectively, were taken before and after cleaning. The wipe and vacuum sample data indicated that both cleaning methods substantially reduced dust lead levels (p < 0.001). The mean percent reductions in lead loading were approximately 29% and 40% for the VAC-VAC and VAC-DSC-VAC interventions, respectively. The difference between the two postcleaning levels was statistically significant by wipe sampling (p = 0.038) but was marginally insignificant by vacuum sampling (p = 0.072). A subset of sample data collected before repeat vacuuming (VAC-DSC) suggested that repeat vacuuming after dry steam cleaning is unnecessary. In summary, slow and steady HEPA vacuuming with the help of a dust finder indicator reduces surface and overall lead dust in carpets, and dry steam cleaning further reduces surface lead contamination as compared with HEPA vacuuming alone.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18075882     DOI: 10.1080/15459620701805169

Source DB:  PubMed          Journal:  J Occup Environ Hyg        ISSN: 1545-9624            Impact factor:   2.155


  3 in total

1.  Evaluation of HEPA vacuum cleaning and dry steam cleaning in reducing levels of polycyclic aromatic hydrocarbons and house dust mite allergens in carpets.

Authors:  Chang Ho Yu; Lih-Ming Yiin; Zhi-Hua Tina Fan; George G Rhoads
Journal:  J Environ Monit       Date:  2008-11-06

2.  Exposure to Beta-(1,3)-D-glucan in house dust at age 7-10 is associated with airway hyperresponsiveness and atopic asthma by age 11-14.

Authors:  Dharini Maheswaran; Yiye Zeng; Moira Chan-Yeung; James Scott; Alvaro Osornio-Vargas; Allan B Becker; Anita L Kozyrskyj
Journal:  PLoS One       Date:  2014-06-06       Impact factor: 3.240

3.  Remediating Thirdhand Smoke Pollution in Multiunit Housing: Temporary Reductions and the Challenges of Persistent Reservoirs.

Authors:  Georg E Matt; Penelope J E Quintana; Eunha Hoh; Joy M Zakarian; Nathan G Dodder; Rachael A Record; Melbourne F Hovell; E Melinda Mahabee-Gittens; Samuel Padilla; Laura Markman; Kayo Watanabe; Thomas E Novotny
Journal:  Nicotine Tob Res       Date:  2021-01-22       Impact factor: 4.244

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.