Reliability of bone scintigraphy for suspected scaphoid fractures.

Frank J P Beeres1, Mike Hogervorst, Steven J Rhemrev, Saskia Le Cessie, Jan Willem Arndt, Marcel P M Stokkel, Kees A Bartlema, Jaap F Hamming.   

Abstract

PURPOSE: To examine the observer variation for bone scintigraphy in the detection of occult scaphoid fractures in daily practice, using only the early bone scanning images.
METHODS: One hundred bone scans of patients with a suspected scaphoid fracture but negative initial radiographs were prospectively included to calculate the inter- and intraobserver variation. Three nuclear medicine physicians independently evaluated all bone scans at 2 different points in time with a 3-month interval. The observers filled out a blinded scoring sheet for each patient. They scored if a scaphoid fracture was present or not. In addition, they scored the presence or absence of another fracture. The inter- and intraobserver variation was analyzed using the kappa statistic.
RESULTS: The interobserver variation showed substantial agreement for a scaphoid fracture and almost perfect agreement for another fracture. The intraobserver variation showed almost perfect agreement for both a scaphoid fracture and another fracture.
CONCLUSIONS: In the present study, early static images of bone scintigraphy for suspected scaphoid fractures showed very little inter- and intraobserver variation. In addition, expertise does not seem to have a negative influence on the results. This enhances the possibility of using bone scintigraphy in daily practice.

Entities:  

Mesh:

Year:  2007        PMID: 18075414     DOI: 10.1097/RLU.0b013e318156bb91

Source DB:  PubMed          Journal:  Clin Nucl Med        ISSN: 0363-9762            Impact factor:   7.794


  1 in total

1.  A Scoring System to Demonstrate the Risk for Bone Injury in Patients with Clinically Suspected or Occult Scaphoid Fracture.

Authors:  H Bahadir Gokcen; Mehmet Akif Akcal; Koray Unay; Selahattin Ozyurek; Oguz Poyanli; Irfan Esenkaya
Journal:  Indian J Orthop       Date:  2018 Mar-Apr       Impact factor: 1.251