Literature DB >> 18075209

Use of field-portable X-ray fluorescence (FPXRF) analyzer to measure airborne lead levels in Korean workplaces.

Nam-Soo Kim1, Jin-Ho Kim, Kyu-Dong Ahn, Byung-Kook Lee.   

Abstract

We evaluated the possibility of applying field-portable x-ray fluorescence (FPXRF) analysis as a rapid, on-site and near real-time method for evaluating airborne lead contamination in Korean workplaces. A total of 287 airborne lead filter samples were measured in 12 lead-using workplaces during routine industrial hygienic monitoring procedures as required by Korean government regulations. All filter samples were collected using the standard industrial hygiene sampling protocol described in NIOSH Method 7300 using closed-face 37-mm cassettes with preloaded cellulose ester membrane filters with a pore size of 0.8 microm. The samples were first analyzed using the non-destructive, FPXRF analytical method (NIOSH method 7702), and then subsequently analyzed using inductively coupled plasma atomic emission spectrophotometry (ICP) (NIOSH method 7300) as a reference analytical method. Pair-wise comparison of filter samples using the paired t-test revealed no statistically significant differences between the two methods over a wide range of airborne lead levels (0.018-0.201 microg/m(3)) either over the industries assessed or separately in the 12 lead-using workplaces. Linear regression of the data between the ICP and FPXRF methods produced a slope of 1.03, a y-intercept of 0.13 microg/sample, and a coefficient of determinant (r(2)) of 0.975 for all the data. For samples in the range from 0 to 100 microg, the corresponding values were 1.07, -1.20 microg/sample, and 0.925, respectively. There were no significant differences in the regression analyses of the three industry types (r(2)=0.964-0.982). Our data suggest that FPXRF data are highly correlated with those from the laboratory-based ICP method in terms of accuracy, precision, and bias. Therefore, FPXRF can be used for the rapid, on-site analysis of lead air-filter samples for values up to 26 microg/sample prior to laboratory confirmation by the ICP method.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 18075209     DOI: 10.1539/joh.49.493

Source DB:  PubMed          Journal:  J Occup Health        ISSN: 1341-9145            Impact factor:   2.708


  2 in total

1.  Assessment of occupational exposure to manganese and other metals in welding fumes by portable X-ray fluorescence spectrometer.

Authors:  Wisanti Laohaudomchok; Jennifer M Cavallari; Shona C Fang; Xihong Lin; Robert F Herrick; David C Christiani; Marc G Weisskopf
Journal:  J Occup Environ Hyg       Date:  2010-08       Impact factor: 2.155

2.  Immediate screening of lead exposure in the workplace using portable X-ray fluorescence.

Authors:  Jean-Philippe Gorce; Martin Roff
Journal:  J Occup Environ Hyg       Date:  2016       Impact factor: 2.155

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.