Literature DB >> 18074476

Patient-initiated device removal in intensive care units: a national prevalence study.

Lorraine C Mion1, Ann F Minnick, Rosanne Leipzig, Catherine D Catrambone, Mary E Johnson.   

Abstract

OBJECTIVE: Information is needed about patient-initiated device removal to guide quality initiatives addressing regulations aimed at minimizing physical restraint use. Research objectives were to determine the prevalence of device removal, describe patient contexts, examine unit-level adjusted risk factors, and describe consequences.
DESIGN: Prospective prevalence.
SETTING: Total of 49 adult intensive care units (ICUs) from a random sample of 39 hospitals in five states.
METHODS: Data were collected daily for 49,482 patient-days by trained nurses and included unit census, ventilator days, restraint days, and days accounted for by men and by elderly. For each device removal episode, data were collected on demographic and clinical variables.
RESULTS: Patients removed 1,623 devices on 1,097 occasions: overall rate, 22.1 episodes/1000 patient-days; range, 0-102.4. Surgical ICUs had lower rates (16.1 episodes) than general (23.6 episodes) and medical (23.4 episodes) ICUs. ICUs with fewer resources had fewer all-type device removal relative to ICUs with greater resources (relative risk, 0.76; 95% confidence interval, 0.66-0.87) but higher self-extubation rates (relative risk, 1.27; 95% confidence interval, 1.07-1.52). Men accounted for 57% of the episodes, 44% were restrained at the time, and 30% had not received any sedation, narcotic, or psychotropic drug in the previous 24 hrs. There was no association between rates of device removal with restraint rates, proportion of men, or elderly. Self-extubation rates were inversely associated with ventilator days (rs = -0.31, p = .03). Patient harm occurred in 250 (23%) episodes; ten incurred major harm. No deaths occurred. Reinsertion rates varied by device: 23.5% of surgical drains to 88.9% of monitor leads. Additional resources (e.g., radiography) were used in 58% of the episodes.
CONCLUSION: Device removal by ICU patients is common, resulting in harm in one fourth of patients and significant resource expenditure. Further examination of patient-, unit-, and practitioner-level variables may help explain variation in rates and provide direction for further targeted interventions.

Entities:  

Mesh:

Year:  2007        PMID: 18074476     DOI: 10.1097/01.ccm.0000291651.12767.52

Source DB:  PubMed          Journal:  Crit Care Med        ISSN: 0090-3493            Impact factor:   7.598


  16 in total

1.  [Anonymous critical incident reporting system. Implementation in an intensive care unit].

Authors:  M Hübler; A Möllemann; M Regner; T Koch; M Ragaller
Journal:  Anaesthesist       Date:  2008-09       Impact factor: 1.041

2.  Head and neck surgical patients; is it time for a bridle era?

Authors:  Michelle Carey; Ali Al-Hussaini; Ameeth Sanu; David Owens
Journal:  Eur Arch Otorhinolaryngol       Date:  2013-11-16       Impact factor: 2.503

3.  Ten tips for ICU sedation.

Authors:  Sangeeta Mehta; Claudia Spies; Yahya Shehabi
Journal:  Intensive Care Med       Date:  2017-11-18       Impact factor: 17.440

4.  A randomized evaluation of bispectral index-augmented sedation assessment in neurological patients.

Authors:  Daiwai M Olson; Suzanne M Thoyre; Eric D Peterson; Carmelo Graffagnino
Journal:  Neurocrit Care       Date:  2009-01-29       Impact factor: 3.210

5.  [Sedation and weaning in neurocritical care: can concepts from general critical care be applied?].

Authors:  J Bösel; R Dziewas
Journal:  Nervenarzt       Date:  2012-12       Impact factor: 1.214

6.  Physical restraint in critical care settings: will they go away?

Authors:  Lorraine C Mion
Journal:  Geriatr Nurs       Date:  2008 Nov-Dec       Impact factor: 2.361

Review 7.  Defining sedation-related adverse events in the pediatric intensive care unit.

Authors:  Mary Jo C Grant; Michele C Balas; Martha A Q Curley
Journal:  Heart Lung       Date:  2013 May-Jun       Impact factor: 2.210

8.  Interventions to decrease tube, line, and drain removals in intensive care units: the FRATER study.

Authors:  Silvia Calvino Günther; Carole Schwebel; Aurélien Vésin; Judith Remy; Geraldine Dessertaine; Jean-François Timsit
Journal:  Intensive Care Med       Date:  2009-06-26       Impact factor: 17.440

9.  Risk factors and outcomes after unplanned extubations on the ICU: a case-control study.

Authors:  Robin I de Groot; Olaf M Dekkers; Ingeborg Hf Herold; Evert de Jonge; M Sesmu Arbous
Journal:  Crit Care       Date:  2011-01-13       Impact factor: 9.097

10.  A retrospective analysis of determinants of self-extubation in a tertiary care intensive care unit.

Authors:  Preet Mohinder Singh; Vimi Rewari; Mahesh Kumar Arora; Anjan Trikha
Journal:  J Emerg Trauma Shock       Date:  2013-10
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.