Thermal comfort in naturally ventilated and air-conditioned buildings in humid subtropical climate zone in China.

Wei Yang1, Guoqiang Zhang.   

Abstract

A thermal comfort field study has been carried out in five cities in the humid subtropical climate zone in China. The survey was performed in naturally ventilated and air-conditioned buildings during the summer season in 2006. There were 229 occupants from 111 buildings who participated in this study and 229 questionnaire responses were collected. Thermal acceptability assessment reveals that the indoor environment in naturally ventilated buildings could not meet the 80% acceptability criteria prescribed by ASHRAE Standard 55, and people tended to feel more comfortable in air-conditioned buildings with the air-conditioned occupants voting with higher acceptability (89%) than the naturally ventilated occupants (58%). The neutral temperatures in naturally ventilated and air-conditioned buildings were 28.3 degrees C and 27.7 degrees C, respectively. The range of accepted temperature in naturally ventilated buildings (25.0-31.6 degrees C) was wider than that in air-conditioned buildings (25.1-30.3 degrees C), which suggests that occupants in naturally ventilated buildings seemed to be more tolerant of higher temperatures. Preferred temperatures were 27.9 degrees C and 27.3 degrees C in naturally ventilated and air-conditioned buildings, respectively, both of which were 0.4 degrees C cooler than neutral temperatures. This result suggests that people of hot climates may use words like "slightly cool" to describe their preferred thermal state. The relationship between draught sensation and indoor air velocity at different temperature ranges indicates that indoor air velocity had a significant influence over the occupants' comfort sensation, and air velocities required by occupants increased with the increasing of operative temperatures. Thus, an effective way of natural ventilation which can create the preferred higher air movement is called for. Finally, the indoor set-point temperature of 26 degrees C or even higher in air-conditioned buildings was confirmed as making people comfortable, which supports the regulation in China that in public and office buildings the set-point temperature of air-conditioning system should not be lower than 26 degrees C.

Entities:  

Mesh:

Year:  2007        PMID: 18074157     DOI: 10.1007/s00484-007-0133-4

Source DB:  PubMed          Journal:  Int J Biometeorol        ISSN: 0020-7128            Impact factor:   3.787


  1 in total

1.  Field study of a thermal environment and adaptive model in Shanghai.

Authors:  X J Ye; Z P Zhou; Z W Lian; H M Liu; C Z Li; Y M Liu
Journal:  Indoor Air       Date:  2006-08       Impact factor: 5.770

  1 in total
  5 in total

1.  Building and indoor environmental quality assessment of Nigerian primary schools: A pilot study.

Authors:  Oluyemi Toyinbo; Wanda Phipatanakul; Richard Shaughnessy; Ulla Haverinen-Shaughnessy
Journal:  Indoor Air       Date:  2019-03-20       Impact factor: 5.770

2.  Air movement preferences observed in naturally ventilated buildings in humid subtropical climate zone in China.

Authors:  Wei Yang; Guoqiang Zhang
Journal:  Int J Biometeorol       Date:  2009-07-19       Impact factor: 3.787

3.  A comparative analysis of human thermal conditions in outdoor urban spaces in the summer season in Singapore and Changsha, China.

Authors:  Wei Yang; Nyuk Hien Wong; Guoqiang Zhang
Journal:  Int J Biometeorol       Date:  2012-12-20       Impact factor: 3.787

4.  Investigation of the effects of face masks on thermal comfort in Guangzhou, China.

Authors:  Tianwei Tang; Yongcheng Zhu; Xiaoqing Zhou; Zhisheng Guo; Yudong Mao; Huilin Jiang; Zhaosong Fang; Zhimin Zheng; Xiaohui Chen
Journal:  Build Environ       Date:  2022-02-23       Impact factor: 6.456

5.  Anchoring biases affect repeated scores of thermal, moisture, tactile and comfort sensations in transient conditions.

Authors:  Margherita Raccuglia; Christian Heyde; Alex Lloyd; Daniel Ruiz; Simon Hodder; George Havenith
Journal:  Int J Biometeorol       Date:  2018-08-07       Impact factor: 3.787