Literature DB >> 18073615

Resorbable fillers reduce stress risers from empty screw holes.

J Winslow Alford1, Michael P Bradley, Paul D Fadale, Joseph J Crisco, Douglas C Moore, Michael G Ehrlich.   

Abstract

BACKGROUND: Empty screw holes after hardware removal are stress risers that weaken bone and can lead to refracture in an active individual. We sought to reduce these stress risers. We hypothesize that resorbable screws used as hole fillers would (1) provide immediate strength and (2) maintain this strength during resorption.
METHODS: Randomized, prospective controlled animal laboratory study with 75 live New Zealand white rabbits' paired femurs. Single mid-diaphyseal holes were filled with a metal or resorbable screw; contralateral femurs were paired empty hole controls. Main outcome measurements included histologic analysis, torsion to failure, peak torque, energy to failure, and stiffness at baseline, 1 week, and 13 weeks postimplantation.
RESULTS: At time baseline, resorbable fillers produced an immediate 30% increase in the peak torque (p = 0.01) and 73% increase in peak energy (p = 0.006). Metal screws produced a 17% increase in peak torque (p = 0.038), and a 58% increase in the amount of energy to failure (p = 0.009). At 1 week, although the resorbable (p = 0.01) but not the metal (p = 0.82) screws increased the peak torque, both metal (p = 0.003) and resorbable (p = 0.050) screws increased the peak energy compared with contralateral empty controls. At 13 weeks, metal and resorbable screw-filled bones were as strong as the healed contralateral femurs. Partial screw resorption and new bone formation without lysis was demonstrated histologically. Resorbable screw hole fillers immediately increase the strength of bones without weakening during early resorption.
CONCLUSIONS: Placing resorbable fillers in bone defects after hardware removal could reduce the likelihood of refracture.

Entities:  

Mesh:

Year:  2007        PMID: 18073615     DOI: 10.1097/01.ta.0000221042.09862.ae

Source DB:  PubMed          Journal:  J Trauma        ISSN: 0022-5282


  4 in total

1.  Fracture after bisphosphonate treatment in children with cerebral palsy: the role of stress risers.

Authors:  H Theodore Harcke; Kimberly L Stevenson; Heidi H Kecskemethy; Steven J Bachrach; Leslie E Grissom
Journal:  Pediatr Radiol       Date:  2011-08-30

2.  Incidence and Characteristics of Humeral Shaft Fractures After Subpectoral Biceps Tenodesis.

Authors:  Archie L Overmann; Donald F Colantonio; Benjamin M Wheatley; William R Volk; Kelly G Kilcoyne; Jonathan F Dickens
Journal:  Orthop J Sports Med       Date:  2019-03-28

Review 3.  Shape-Memory Materials via Electrospinning: A Review.

Authors:  Valentina Salaris; Adrián Leonés; Daniel Lopez; José Maria Kenny; Laura Peponi
Journal:  Polymers (Basel)       Date:  2022-02-28       Impact factor: 4.329

4.  Open Screw Placement in a 1.5 mm LCP Over a Fracture Gap Decreases Fatigue Life.

Authors:  Sarah G J Alwen; Amy S Kapatkin; Tanya C Garcia; Joshua Milgram; Susan M Stover
Journal:  Front Vet Sci       Date:  2018-05-23
  4 in total