Literature DB >> 18070803

Why does exercise terminate at the maximal lactate steady state intensity?

B Baron1, T D Noakes, J Dekerle, F Moullan, S Robin, R Matran, P Pelayo.   

Abstract

OBJECTIVE: The purpose of this study was to measure physiological responses during exercise performed until exhaustion at the exercise intensity corresponding to the maximal lactate steady state (MLSS) in order to determine why subjects stopped.
METHODS: Eleven male trained subjects performed a test at MLSS on a cycle ergometer until exhaustion.
RESULTS: Time to exhaustion was 55.0 (SD 8.5) min. No variation was observed between the 10th and the last minute for arterial pyruvate, bicarbonate, and haemoglobin concentrations, redox state, arterial oxygen pressure, arterial oxygen saturation, osmolality, haematocrit, oxygen uptake, carbon dioxide output, and gas exchange ratio (p>0.05). Arterial lactate concentration and arterial carbon dioxide pressure decreased significantly whereas pH, base excess and the Ratings of Perceived Exertion (RPE) increased significantly (p<0.05). Although respiratory rate, minute ventilation and heart rate increased significantly until exhaustion (p<0.05), values at termination of the MLSS test were significantly lower than values measured during a maximal exercise test (p<0.05). Blood ammonia concentrations rose progressively during the MLSS test. However, there is no known mechanism by which this change could cause peripheral fatigue.
CONCLUSIONS: Exercise termination was not associated with evidence of failure in any physiological system during prolonged exercise performed at MLSS. Thus the biological mechanisms of exercise termination at MLSS were compatible with an integrative homoeostatic control of peripheral physiological systems during exercise.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 18070803     DOI: 10.1136/bjsm.2007.040444

Source DB:  PubMed          Journal:  Br J Sports Med        ISSN: 0306-3674            Impact factor:   13.800


  17 in total

1.  The eccentric muscle loading influences the pacing strategies during repeated downhill sprint intervals.

Authors:  B Baron; F Deruelle; F Moullan; G Dalleau; C Verkindt; T D Noakes
Journal:  Eur J Appl Physiol       Date:  2008-12-19       Impact factor: 3.078

2.  Time to exhaustion at maximal lactate steady state is similar for cycling and running in moderately trained subjects.

Authors:  Piero Fontana; Urs Boutellier; Claudia Knöpfli-Lenzin
Journal:  Eur J Appl Physiol       Date:  2009-06-24       Impact factor: 3.078

Review 3.  Is it time to retire the 'central governor'?

Authors:  Roy J Shephard
Journal:  Sports Med       Date:  2009       Impact factor: 11.136

4.  Is it time to retire the A.V. Hill Model?: A rebuttal to the article by Professor Roy Shephard.

Authors:  Timothy D Noakes
Journal:  Sports Med       Date:  2011-04-01       Impact factor: 11.136

5.  Six weeks of aerobic training improves VO2max and MLSS but does not improve the time to fatigue at the MLSS.

Authors:  Thiago Teixeira Mendes; Tatiana Ramos Fonseca; Guilherme Passos Ramos; Carolina Franco Wilke; Christian Emmanuel Torres Cabido; Cristiano Lino Monteiro De Barros; André Maia Lima; Lucas de Avila Carvalho Fleury Mortimer; Moisés Vieira de Carvalho; Mauro Martins Teixeira; Nilo Resende Viana Lima; Emerson Silami Garcia
Journal:  Eur J Appl Physiol       Date:  2012-10-05       Impact factor: 3.078

Review 6.  A critical review of critical power.

Authors:  Raffy Dotan
Journal:  Eur J Appl Physiol       Date:  2022-03-18       Impact factor: 3.346

Review 7.  Lactate threshold concepts: how valid are they?

Authors:  Oliver Faude; Wilfried Kindermann; Tim Meyer
Journal:  Sports Med       Date:  2009       Impact factor: 11.136

8.  The midpoint between ventilatory thresholds approaches maximal lactate steady state intensity in amateur cyclists.

Authors:  A B Peinado; Dm Pessôa Filho; V Díaz; P J Benito; M Álvarez-Sánchez; A G Zapico; F J Calderón
Journal:  Biol Sport       Date:  2016-10-10       Impact factor: 2.806

9.  Supplementation with a Polyphenol-Rich Extract, PerfLoad®, Improves Physical Performance during High-Intensity Exercise: A Randomized, Double Blind, Crossover Trial.

Authors:  Julien Cases; Cindy Romain; Cristian Marín-Pagán; Linda H Chung; José Miguel Rubio-Pérez; Caroline Laurent; Sylvie Gaillet; Emmanuelle Prost-Camus; Michel Prost; Pedro E Alcaraz
Journal:  Nutrients       Date:  2017-04-24       Impact factor: 5.717

10.  Muscle MCT4 Content Is Correlated with the Lactate Removal Ability during Recovery Following All-Out Supramaximal Exercise in Highly-Trained Rowers.

Authors:  Hugo Maciejewski; Muriel Bourdin; Léonard Féasson; Hervé Dubouchaud; Christian Denis; Hubert Freund; Laurent A Messonnier
Journal:  Front Physiol       Date:  2016-06-10       Impact factor: 4.566

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.