Literature DB >> 18070654

External fixation of distal radius fractures.

David J Slutsky1.   

Abstract

External fixation has been used for the treatment of distal radius fractures for more than 50 years. Although the fixator configurations have undergone considerable modification over time, the type of fixator itself is not as important as the underlying principles that provide the foundation for external fixation. Although volar plate fixation is currently in vogue, the indications for external fixation remain largely unchanged. Newer fixator designs have also expanded the traditional usage to include nonbridging applications that allow early wrist motion. The following discussion focuses on the myriad uses for external fixation as well as the shortcomings and potential pitfalls.

Entities:  

Mesh:

Year:  2007        PMID: 18070654     DOI: 10.1016/j.jhsa.2007.09.009

Source DB:  PubMed          Journal:  J Hand Surg Am        ISSN: 0363-5023            Impact factor:   2.230


  6 in total

1.  Dorsal Bridge Plating versus External Fixation for Distal Radius Fractures.

Authors:  William L Wang; Asif M Ilyas
Journal:  J Wrist Surg       Date:  2019-08-08

2.  Postoperative early and proactive grip strength training program for distal radius fractures promotes earlier recovery of grip strength: A retrospective study.

Authors:  Yoshio Kaji; Konosuke Yamaguchi; Yumi Nomura; Kunihiko Oka; Osamu Nakamura; Yoichi Ishibashi; Tetsuji Yamamoto
Journal:  Medicine (Baltimore)       Date:  2022-05-13       Impact factor: 1.817

3.  Long term outcomes of open reduction internal fixation versus external fixation of distal radius fractures: A meta-analysis.

Authors:  Conor Gouk; Shu-Kay Ng; Matthew Knight; Randy Bindra; Michael Thomas
Journal:  Orthop Rev (Pavia)       Date:  2019-09-24

4.  3D Printing Adjustable Stiffness External Fixator for Mechanically Stimulated Healing of Tibial Fractures.

Authors:  Hongwei Li; Dichen Li; Feng Qiao; Lei Tang; Qi Han
Journal:  Biomed Res Int       Date:  2021-12-23       Impact factor: 3.411

5.  External fixation of fractures of the distal radius: a randomized comparison of the Hoffman compact II non-bridging fixator and the Dynawrist fixator in 75 patients followed for 1 year.

Authors:  Yngvar Krukhaug; Stein Ugland; Stein A Lie; Leiv M Hove
Journal:  Acta Orthop       Date:  2009-02       Impact factor: 3.717

6.  External fixation versus volar locking plate for displaced intra-articular distal radius fractures: a prospective randomized comparative study of the functional outcomes.

Authors:  Rajeev Shukla; Ravi Kant Jain; Neeraj K Sharma; Ravindra Kumar
Journal:  J Orthop Traumatol       Date:  2014-09-06
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.