Literature DB >> 18067905

Determination of relative response factors of impurities in paclitaxel with high performance liquid chromatography equipped with ultraviolet and charged aerosol detectors.

Ping Sun1, Xiande Wang, Lori Alquier, Cynthia A Maryanoff.   

Abstract

A case study was conducted to determine the relative response factors (RRFs) of paclitaxel-related impurities by high performance liquid chromatography (HPLC) equipped with an ultraviolet (UV) detector and charged aerosol detector (CAD) in tandem. The peak response using CAD was independent of analyte structure in an isocratic analysis for this application. After a sample containing known and unknown impurities was analyzed with HPLC-UV-CAD, an empirical approach was developed to calculate the RRFs for all impurities. The RRFs of known impurities were also determined by linear calibration curves. For known impurities, the RRFs values determined with two approaches are comparable. The new approach is effective yet simpler to determine the RRFs for unknown impurities or degradation products since the need for obtaining authentic pure materials was eliminated.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 18067905     DOI: 10.1016/j.chroma.2007.11.035

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  5 in total

1.  Determination of Gentamicin Sulphate Composition and Related Substances in Pharmaceutical Preparations by LC with Charged Aerosol Detection.

Authors:  Karolina Stypulkowska; Agata Blazewicz; Zbigniew Fijalek; Katarzyna Sarna
Journal:  Chromatographia       Date:  2010-10-01       Impact factor: 2.044

2.  13C NMR spectroscopy for the quantitative determination of compound ratios and polymer end groups.

Authors:  Douglas A L Otte; Dorothee E Borchmann; Chin Lin; Marcus Weck; K A Woerpel
Journal:  Org Lett       Date:  2014-03-06       Impact factor: 6.005

3.  One single amino Acid for estimation the content of total free amino acids in qingkailing injection using high-performance liquid chromatography-diode array detection.

Authors:  Li Zhang; Xue Wang; Jiankun Su; Haiyu Liu; Zhixin Zhang; Lingling Qin; Cheng He; Long Peng; Mingxing Guo; Xiaoyan Gao
Journal:  J Anal Methods Chem       Date:  2014-03-13       Impact factor: 2.193

4.  Validated HPLC Method for the Determination of Paclitaxel-related Substances in an Intravenous Emulsion Loaded with a Paclitaxel-Cholesterol Complex.

Authors:  X J Xia; J Peng; P X Zhang; D J Jin; Y L Liu
Journal:  Indian J Pharm Sci       Date:  2013-11       Impact factor: 0.975

5.  Simultaneous determination of 2 aconitum alkaloids and 12 ginsenosides in Shenfu injection by ultraperformance liquid chromatography coupled with a photodiode array detector with few markers to determine multicomponents.

Authors:  Ai-Hua Ge; Jin Li; Sineeporn Donnapee; Yang Bai; Jiao Liu; Jun He; Er-Wei Liu; Li-Yuan Kang; Xiu-Mei Gao; Yan-Xu Chang
Journal:  J Food Drug Anal       Date:  2014-12-18       Impact factor: 6.157

  5 in total