Literature DB >> 18066542

Paediatric CT: the effects of increasing image noise on pulmonary nodule detection.

Shonit Punwani1, Jie Zhang, Warren Davies, Rebecca Greenhalgh, Paul Humphries.   

Abstract

BACKGROUND: A radiation dose of any magnitude can produce a detrimental effect manifesting as an increased risk of cancer. Cancer development may be delayed for many years following radiation exposure. Minimizing radiation dose in children is particularly important. However, reducing the dose can reduce image quality and may, therefore, hinder lesion detection.
OBJECTIVE: We investigated the effects of reducing the image signal-to-noise ratio (SNR) on CT lung nodule detection for a range of nodule sizes.
MATERIALS AND METHODS: A simulated nodule was placed at the periphery of the lung on an axial CT slice using image editing software. Multiple copies of the manipulated image were saved with various levels of superimposed noise. The image creation process was repeated for a range of nodule sizes. For a given nodule size, output images were read independently by four Fellows of The Royal College of Radiologists.
RESULTS: The overall sensitivities in detecting nodules for the SNR ranges 0.8-0.99, 1-1.49, and 1.5-2.35 were 40.5%, 77.3% and 90.3%, respectively, and the specificities were 47.9%, 73.3% and 75%, respectively. The sensitivity for detecting lung nodules increased with nodule size and increasing SNR. There was 100% sensitivity for the detection of nodules of 4-10 mm in diameter at SNRs greater than 1.5.
CONCLUSION: Reducing medical radiation doses in children is of paramount importance. For chest CT examinations this may be counterbalanced by reduced sensitivity and specificity combined with an increased uncertainty of pulmonary nodule detection. This study demonstrates that pulmonary nodules of 4 mm and greater in diameter can be detected with 100% sensitivity provided that the perceived image SNR is greater than 1.5.

Entities:  

Mesh:

Year:  2007        PMID: 18066542     DOI: 10.1007/s00247-007-0694-8

Source DB:  PubMed          Journal:  Pediatr Radiol        ISSN: 0301-0449


  31 in total

1.  Dose reduction in pediatric CT: a rational approach.

Authors:  John M Boone; Estella M Geraghty; J Anthony Seibert; Sandra L Wootton-Gorges
Journal:  Radiology       Date:  2003-08       Impact factor: 11.105

2.  Nodule detection in digital chest radiography: part of image background acting as pure noise.

Authors:  Magnus Båth; Markus Håkansson; Sara Börjesson; Susanne Kheddache; Anna Grahn; François O Bochud; Francis R Verdun; Lars Gunnar Månsson
Journal:  Radiat Prot Dosimetry       Date:  2005       Impact factor: 0.972

3.  Helical CT of the body: are settings adjusted for pediatric patients?

Authors:  A Paterson; D P Frush; L F Donnelly
Journal:  AJR Am J Roentgenol       Date:  2001-02       Impact factor: 3.959

4.  Estimated risks of radiation-induced fatal cancer from pediatric CT.

Authors:  D Brenner; C Elliston; E Hall; W Berdon
Journal:  AJR Am J Roentgenol       Date:  2001-02       Impact factor: 3.959

5.  Pulmonary nodules resected at video-assisted thoracoscopic surgery: etiology in 426 patients.

Authors:  M S Ginsberg; S K Griff; B D Go; H H Yoo; L H Schwartz; D M Panicek
Journal:  Radiology       Date:  1999-10       Impact factor: 11.105

6.  Appendicitis in children: low-dose CT with a phantom-based simulation technique--initial observations.

Authors:  Nancy R Fefferman; Elan Bomsztyk; Angela M Yim; Rafael Rivera; John B Amodio; Lynne P Pinkney; Naomi A Strubel; Marilyn E Noz; Henry Rusinek
Journal:  Radiology       Date:  2005-09-16       Impact factor: 11.105

7.  Effects of reduced exposure on computed radiography: comparison of nodule detection accuracy with conventional and asymmetric screen-film radiographs of a chest phantom.

Authors:  C Kimme-Smith; D R Aberle; J W Sayre; E M Hart; S M Greaves; K Brown; D A Young; M D Deseran; T Johnson; S L Johnson
Journal:  AJR Am J Roentgenol       Date:  1995-08       Impact factor: 3.959

8.  Paediatric pulmonary nodules: a comparison of computed tomography, thoracotomy findings and histology.

Authors:  P L Robertson; D W Boldt; J F De Campo
Journal:  Clin Radiol       Date:  1988-11       Impact factor: 2.350

Review 9.  Cancer risks following diagnostic and therapeutic radiation exposure in children.

Authors:  Ruth A Kleinerman
Journal:  Pediatr Radiol       Date:  2006-09

Review 10.  Multidetector row CT for imaging the paediatric tracheobronchial tree.

Authors:  Georgia Papaioannou; Carolyn Young; Catherine M Owens
Journal:  Pediatr Radiol       Date:  2007-04-25
View more
  2 in total

Review 1.  Volume versus diameter assessment of small pulmonary nodules in CT lung cancer screening.

Authors:  Daiwei Han; Marjolein A Heuvelmans; Matthijs Oudkerk
Journal:  Transl Lung Cancer Res       Date:  2017-02

2.  Detection of pulmonary nodules at paediatric CT: maximum intensity projections and axial source images are complementary.

Authors:  Fleur Kilburn-Toppin; Owen J Arthurs; Angela D Tasker; Patricia A K Set
Journal:  Pediatr Radiol       Date:  2013-01-24
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.