Literature DB >> 18063186

Radial nerve palsy after arthroscopic anterior capsular release for degenerative elbow contracture.

Jin-Young Park1, Chul-Hyun Cho, Jin-Hyung Choi, Sung-Tae Lee, Chul-Hyung Kang.   

Abstract

Because the use of arthroscopy has increased recently for the treatment of elbow lesions, reports of complications have become more common. Nerve injury after arthroscopic anterior capsular release is an extremely rare complication, with 4 reported cases worldwide. We usually use a sharp-tipped electrocautery device with a 0.5-mm diameter during arthroscopic capsular release. In this case, because the former was not prepared, we used a ball-tipped electrocautery device with a 3-mm diameter. Herein, we experienced a case of radial nerve palsy after arthroscopic anterior capsular release using a ball-tipped electrocautery device on a degenerative elbow contracture. We supposed that the electrocautery device caused transiently thermal injury of the radial nerve despite proper portal entry site, intra-articular distension, and gentle arthroscopic manipulation. Elbow arthroscopy remains a technically difficult procedure with the potential for neurologic complications. To perform surgery safely, knowledge of the regional neuroanatomy and a thorough understanding of proper instrument usage are required.

Entities:  

Mesh:

Year:  2007        PMID: 18063186     DOI: 10.1016/j.arthro.2006.11.021

Source DB:  PubMed          Journal:  Arthroscopy        ISSN: 0749-8063            Impact factor:   4.772


  5 in total

1.  Portal placement in elbow arthroscopy by novice surgeons: cadaver study.

Authors:  Femke M A P Claessen; Amir R Kachooei; Gregory P Kolovich; Geert A Buijze; Luke S Oh; Michel P J van den Bekerom; Job N Doornberg
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-06-28       Impact factor: 4.342

2.  Elbow Positioning and Joint Insufflation Substantially Influence Median and Radial Nerve Locations.

Authors:  Michael Hackl; Sebastian Lappen; Klaus J Burkhart; Tim Leschinger; Martin Scaal; Lars P Müller; Kilian Wegmann
Journal:  Clin Orthop Relat Res       Date:  2015-07-08       Impact factor: 4.176

3.  Arthroscopic treatment of stiff elbow.

Authors:  Davide Blonna; Enrico Bellato; Eleonora Marini; Michele Scelsi; Filippo Castoldi
Journal:  ISRN Surg       Date:  2011-07-06

Review 4.  Tips to avoid nerve injury in elbow arthroscopy.

Authors:  Nick F J Hilgersom; Luke S Oh; Mark Flipsen; Denise Eygendaal; Michel P J van den Bekerom
Journal:  World J Orthop       Date:  2017-02-18

5.  The Needle-and-Knife Technique: A Safe Technique for Anterolateral Portal Placement in Elbow Arthroscopy.

Authors:  Sutee Thaveepunsan; Maegan N Shields; Shawn W O'Driscoll
Journal:  Orthop J Sports Med       Date:  2019-01-11
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.