Literature DB >> 18063170

Arthroscopic distal clavicle resection: a biomechanical analysis of resection length and joint compliance in a cadaveric model.

Sara L Edwards1, Nicole A Wilson, Steven E Flores, Jason L Koh, Li-Qun Zhang.   

Abstract

PURPOSE: The purposes of this study were to assess the effects of a distal clavicle resection of less than 5 mm on bony contact and compliance in the acromioclavicular (AC) joint and to localize areas of persistent contact in the AC joint. The hypothesis of this study was that AC contact can be avoided by excising less than 5 mm of bone from the distal clavicle.
METHODS: Ten human AC joints underwent compressive loading of the distal clavicle into the acromion after the following: disk excision, distal clavicle resection of 2.5 mm, and distal clavicle resection of 5 mm. The joint resistance force, stiffness, and presence and location of contact were monitored.
RESULTS: Excising 2.5 mm or less resulted in no bone-to-bone abutment in 6 of 10 specimens. A 5-mm resection resulted in successful decompression in all specimens. The specimens that required a 5-mm resection had minimal contact after the 2.5-mm resection (inferior-posterior quadrant only). AC joint stiffness decreased significantly with increasing amounts of clavicular resection (P = .01).
CONCLUSIONS: A 5-mm distal clavicle resection guaranteed no abutment but decreased joint stiffness. Persistent contact occurred only in the inferior-posterior quadrant of the joint after a 2.5-mm resection. CLINICAL RELEVANCE: These findings support the efficacy of a 5-mm distal clavicle resection for eliminating bony contact but suggest that there is a bony contribution to AC joint stiffness. A resection of 2.5 to 5.0 mm could be adequate if care is taken to excise a greater depth of bone in the inferior-posterior quadrant.

Entities:  

Mesh:

Year:  2007        PMID: 18063170     DOI: 10.1016/j.arthro.2007.07.004

Source DB:  PubMed          Journal:  Arthroscopy        ISSN: 0749-8063            Impact factor:   4.772


  8 in total

1.  Clinical review of patients subjected to mini-Mumford arthroscopy.

Authors:  Carlo Biz; Giovanni Battista Vinanti; Marco Zamperetti; Alberto Rossato; Roberto Aldegheri
Journal:  Muscles Ligaments Tendons J       Date:  2012-09-10

Review 2.  [Arthroscopic resection of the acromioclavicular joint].

Authors:  R Lenz; P C Kreuz; T Tischer
Journal:  Oper Orthop Traumatol       Date:  2014-06-14       Impact factor: 1.154

3.  Minimum 10-Year Outcomes After Revision Anatomic Coracoclavicular Ligament Reconstruction for Acromioclavicular Joint Instability.

Authors:  Daniel P Berthold; Lukas N Muench; Knut Beitzel; Simon Archambault; Aulon Jerliu; Mark P Cote; Bastian Scheiderer; Andreas B Imhoff; Robert A Arciero; Augustus D Mazzocca
Journal:  Orthop J Sports Med       Date:  2020-09-16

4.  Comparison between open and arthroscopic procedures for lateral clavicle resection.

Authors:  Nick Duindam; Jesse W P Kuiper; Marco J M Hoozemans; Bart J Burger
Journal:  Int Orthop       Date:  2013-11-10       Impact factor: 3.075

5.  The importance of biomechanical properties in revision acromioclavicular joint stabilization: a scoping review.

Authors:  Felix Dyrna; Daniel P Berthold; Matthias J Feucht; Lukas N Muench; Frank Martetschläger; Andreas B Imhoff; Augustus D Mazzocca; Knut Beitzel
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2019-10-17       Impact factor: 4.342

6.  Preoperative Factors Associated With Subsequent Distal Clavicle Resection After Rotator Cuff Repair.

Authors:  Peter N Chalmers; Erin Granger; Hunter Ross; Robert T Burks; Robert Z Tashjian
Journal:  Orthop J Sports Med       Date:  2019-05-02

7.  A Modified Weaver-Dunn Procedure with or without Chip Bone Graft for the Treatment of Acromioclavicular Joint Separation.

Authors:  Tae-Soo Park; Hyung Bin Park
Journal:  Indian J Orthop       Date:  2019 Jan-Feb       Impact factor: 1.251

Review 8.  [Postoperative Imaging of Rotator Cuff Tear].

Authors:  Min Hee Lee; Hee Jin Park; Ji Na Kim
Journal:  Taehan Yongsang Uihakhoe Chi       Date:  2021-11-30
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.