Literature DB >> 18062983

Quality control in quantification of volatile organic compounds analysed by thermal desorption-gas chromatography-mass spectrometry.

Kristof Demeestere1, Jo Dewulf, Karlien De Roo, Patrick De Wispelaere, Herman Van Langenhove.   

Abstract

This paper presents a detailed study on the calibration of a thermal desorption-gas chromatography-mass spectrometry (TD-GC-MS)-based methodology for quantification of volatile organic compounds (VOCs) in gaseous and liquid samples. For the first time, it is documented to what extent three widely encountered problems affect precise and accurate quantification, and solutions to improve calibration are proposed. The first issue deals with the limited precision in MS quantification, as exemplified by high relative standard deviations (up to 40%, n=5) on response factors of a set of 69 selected VOCs in a volatility range from 16 Pa to 85 kPa at 298 K. The addition of [(2)H(8)]toluene as an internal standard, in gaseous or liquid phase, improves this imprecision by a factor of 5. Second, the matrix in which the standard is dissolved is shown to be highly important towards calibration. Quantification of gaseous VOCs loaded on a sorbent tube using response factors obtained with liquid standards results in systematic deviations of 40-80%. Relative response factors determined by the analysis of sorbent tubes loaded with both analytes and [(2)H(8)]toluene from liquid phase are shown to offer a reliable alternative for quantification of airborne VOCs, without need for expensive and often hardly available gaseous standards. Third, a strategy is proposed involving the determination of a relative response factor being representative for a group of analytes with similar functionalities and electron impact fragmentation patterns. This group method approach indicates to be useful (RSD approximately 10%) for quantifying analytes belonging to that class but having no standards available.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 18062983     DOI: 10.1016/j.chroma.2007.11.036

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  4 in total

1.  Assessment of volatile organic compound removal by indoor plants--a novel experimental setup.

Authors:  Majbrit Dela Cruz; Renate Müller; Bo Svensmark; Jakob Skov Pedersen; Jan H Christensen
Journal:  Environ Sci Pollut Res Int       Date:  2014-03-19       Impact factor: 4.223

2.  Effect of operating and sampling conditions on the exhaust gas composition of small-scale power generators.

Authors:  Marianne Smits; Floris Vanpachtenbeke; Benjamin Horemans; Karolien De Wael; Birger Hauchecorne; Herman Van Langenhove; Kristof Demeestere; Silvia Lenaerts
Journal:  PLoS One       Date:  2012-03-19       Impact factor: 3.240

3.  A Solid Trap and Thermal Desorption System with Application to a Medical Electronic Nose.

Authors:  Xuntao Xu; Fengchun Tian; Simon X Yang; Qi Li; Jia Yan; Jianwei Machacek
Journal:  Sensors (Basel)       Date:  2008-11-04       Impact factor: 3.576

4.  Analysis of relative concentration of ethanol and other odorous compounds (OCs) emitted from the working surface at a landfill in China.

Authors:  Dong Li; Wenjing Lu; Yanjun Liu; Hanwen Guo; Sai Xu; Zhongyuan Ming; Hongtao Wang
Journal:  PLoS One       Date:  2015-03-13       Impact factor: 3.240

  4 in total