Literature DB >> 18062390

Disinfection of Acinetobacter baumannii-contaminated surfaces relevant to medical treatment facilities with ultraviolet C light.

Vipin K Rastogi1, Lalena Wallace, Lisa S Smith.   

Abstract

The efficacy of ultraviolet C (UVC) light (100-280 nm) in the decontamination of three hospital-related surfaces, namely, unpainted/painted aluminum (bed railings), stainless steel (operating tables), and scrubs (laboratory coats), was investigated. Acinetobacter baumannii cells were inoculated (10(5) or 10(3) cells) on small coupons and dried overnight in a class II biosafety cabinet. Drying resulted in < or =50% loss of viability. The UVC fluence of 90 J/m2 was observed to be very effective in the decontamination of cells from all metal coupon surfaces (complete killing). However, the same fluence was ineffective in the decontamination of scrubs. The effectiveness of two other common disinfection practices, that is, 15 minutes of boiling or spraying with 70% ethanol, was investigated for the scrubs. Although ethanol treatment was ineffective, the boiling treatment was very effective (complete killing). These results establish that metal surfaces can be decontaminated with UVC irradiation and boiling treatment is effective for scrub decontamination.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 18062390     DOI: 10.7205/milmed.172.11.1166

Source DB:  PubMed          Journal:  Mil Med        ISSN: 0026-4075            Impact factor:   1.437


  5 in total

1.  Decontamination of targeted pathogens from patient rooms using an automated ultraviolet-C-emitting device.

Authors:  Deverick J Anderson; Maria F Gergen; Emily Smathers; Daniel J Sexton; Luke F Chen; David J Weber; William A Rutala
Journal:  Infect Control Hosp Epidemiol       Date:  2013-05       Impact factor: 3.254

2.  Potential of bacteriophage ΦAB2 as an environmental biocontrol agent for the control of multidrug-resistant Acinetobacter baumannii.

Authors:  Li-Kuang Chen; Yu-Lin Liu; Anren Hu; Kai-Chih Chang; Nien-Tsung Lin; Meng-Jiun Lai; Chun-Chieh Tseng
Journal:  BMC Microbiol       Date:  2013-07-08       Impact factor: 3.605

3.  Impact of chlorine dioxide gas sterilization on nosocomial organism viability in a hospital room.

Authors:  John J Lowe; Shawn G Gibbs; Peter C Iwen; Philip W Smith; Angela L Hewlett
Journal:  Int J Environ Res Public Health       Date:  2013-06-21       Impact factor: 3.390

Review 4.  Applications of ultraviolet germicidal irradiation disinfection in health care facilities: effective adjunct, but not stand-alone technology.

Authors:  Farhad Memarzadeh; Russell N Olmsted; Judene M Bartley
Journal:  Am J Infect Control       Date:  2010-06       Impact factor: 2.918

5.  Use of UV-C radiation to disinfect non-critical patient care items: a laboratory assessment of the Nanoclave Cabinet.

Authors:  Ginny Moore; Shanom Ali; Elaine A Cloutman-Green; Christina R Bradley; Martyn A C Wilkinson; John C Hartley; Adam P Fraise; A Peter R Wilson
Journal:  BMC Infect Dis       Date:  2012-08-03       Impact factor: 3.090

  5 in total