Literature DB >> 18059040

Influence of internal standard charge state on the accuracy of mass measurements in orthogonal acceleration time-of-flight mass spectrometers.

Laurence Charles1.   

Abstract

Accuracy of mass measurements performed in orthogonal acceleration time-of-flight (oa-TOF) mass spectrometers highly depends on the quality of the signal and the internal calibration. The use of two reference compounds which bracket the targeted unknown, give rise to ions with sufficient signal-to-noise ratio while avoiding detector saturation and produce signals of similar intensity as compared to the target is a common requirement which allow a 5 ppm accuracy on a routine basis. Ion charge state is demonstrated here to be an additional and particularly critical parameter. Using internal references of lower charge state than the target ion systematically yielded overestimated data. Errors measured for quadruply charged molecules were in the range 16-18 ppm when mass calibrants were singly charged ions while accuracy was below 5 ppm when references and target ions were in the same charge state. Magnitude of errors was found to increase with the difference in charge state. This phenomenon arises from the orthogonal acceleration of ions in the TOF analyzer, an interface implemented in all TOF mass spectrometers to accommodate continuous beam ionization sources. Copyright (c) 2007 John Wiley & Sons, Ltd.

Year:  2008        PMID: 18059040     DOI: 10.1002/rcm.3347

Source DB:  PubMed          Journal:  Rapid Commun Mass Spectrom        ISSN: 0951-4198            Impact factor:   2.419


  7 in total

1.  Analytical strategy for the molecular weight determination of random copolymers of poly(methyl methacrylate) and poly(methacrylic acid).

Authors:  Rémi Giordanengo; Stéphane Viel; Manuel Hidalgo; Béatrice Allard-Breton; André Thévand; Laurence Charles
Journal:  J Am Soc Mass Spectrom       Date:  2010-02-10       Impact factor: 3.109

2.  Tandem mass spectrometry of trimethylsilyl-terminated poly(dimethylsiloxane) ammonium adducts generated by electrospray ionization.

Authors:  Thierry Fouquet; Stéphane Humbel; Laurence Charles
Journal:  J Am Soc Mass Spectrom       Date:  2011-02-15       Impact factor: 3.109

3.  MS/MS-Assisted Design of Sequence-Controlled Synthetic Polymers for Improved Reading of Encoded Information.

Authors:  Laurence Charles; Gianni Cavallo; Valérie Monnier; Laurence Oswald; Roza Szweda; Jean-François Lutz
Journal:  J Am Soc Mass Spectrom       Date:  2016-12-02       Impact factor: 3.109

4.  Tandem mass spectrometry of poly(methacrylic Acid) oligomers produced by negative mode electrospray ionization.

Authors:  Rémi Giordanengo; Stéphane Viel; Béatrice Allard-Breton; André Thévand; Laurence Charles
Journal:  J Am Soc Mass Spectrom       Date:  2008-09-25       Impact factor: 3.109

5.  Nucleophile addition of reduced glutathione on 2-methyl-2-nitroso compound: a combined electron paramagnetic resonance spectroscopy and electrospray tandem mass spectrometry study.

Authors:  Mathilde Triquigneaux; Béatrice Tuccio; Robert Lauricella; Laurence Charles
Journal:  J Am Soc Mass Spectrom       Date:  2009-08-07       Impact factor: 3.109

6.  Improving the Resolution of Kendrick Mass Defect Analysis for Polymer Ions with Fractional Base Units.

Authors:  Thierry Fouquet; Hiroaki Sato
Journal:  Mass Spectrom (Tokyo)       Date:  2017-03-28

7.  Negative Ion Mode Electrospray Tandem Mass Spectrometry of Hydroxy-Terminated Polydimethylsiloxanes Formed upon in situ Methanolysis.

Authors:  Thierry Fouquet; Laurence Charles; Hiroaki Sato
Journal:  Mass Spectrom (Tokyo)       Date:  2017-06-15
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.