Literature DB >> 18058934

Extending slice coverage for breathhold fat-suppressed T2-weighted fast spin-echo of the liver at 3.0T: application of variable-rate selective-excitation (VERSE) RF pulses.

Indra C van den Bos1, Shahid M Hussain, Gabriel P Krestin, Piotr A Wielopolski.   

Abstract

PURPOSE: To determine the benefits of variable-rate selective-excitation (VERSE) radio frequency (RF) pulses for increased slice coverage in breathhold (BH) fat-suppressed T2-weighted fast spin-echo (FS-T2W-FSE) liver imaging at 3.0T.
MATERIALS AND METHODS: A total of 12 healthy volunteers were imaged on 3.0T, using FS-T2W-FSE. Slice coverage and specific absorption rate (SAR) levels were monitored for VERSE-RF and standard-RF (sRF), respectively. BH time was 25 seconds; slice thickness 3.5 mm. Maximum coverage was recorded for interactive variation of repetition time (TR), bandwidth (BW), and echo-train length (ETL). Image quality was assessed qualitatively and quantitatively.
RESULTS: Total slice coverage was always higher using VERSE-RF, but varied depending on the selected parameters. For BW > or = 62.5 kHz, slice coverage using VERSE increased between 38% (TR = 8200 msec) and 58% (TR = 2500 msec). Maximum coverage was obtained for TR = 5000 msec, ETL = 12, and BW > or = 62.5 kHz; with a mean of 31.8 slices for VERSE-RF and 22.5 slices for sRF, respectively (P < 0.005, 41% increased coverage). SAR was lower for VERSE-RF using BW < 41.67 kHz (P < 0.05), and equal to sRF for higher BW. Image quality was best for TR < or = 5000 msec (P < 0.05). FS was more homogeneous for lower ETL (P < 0.05). Blood suppression was best for TR < or = 5000 msec (P < 0.05).
CONCLUSION: VERSE-RF pulses can be applied for thin-slice BH FS-T2W liver imaging at 3.0T, with significantly improved slice coverage.

Mesh:

Year:  2008        PMID: 18058934     DOI: 10.1002/jmri.21215

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  2 in total

1.  VERSE-guided numerical RF pulse design: a fast method for peak RF power control.

Authors:  Daeho Lee; William A Grissom; Michael Lustig; Adam B Kerr; Pascal P Stang; John M Pauly
Journal:  Magn Reson Med       Date:  2011-08-25       Impact factor: 4.668

2.  Time-optimal design for multidimensional and parallel transmit variable-rate selective excitation.

Authors:  Daeho Lee; Michael Lustig; William A Grissom; John M Pauly
Journal:  Magn Reson Med       Date:  2009-06       Impact factor: 4.668

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.