Literature DB >> 18058114

Arthroscopic double-pulley suture-bridge technique for rotator cuff repair.

Kyung Cheon Kim1, Kwang Jin Rhee, Hyun Dae Shin.   

Abstract

After preparation of the bone bed, two doubly loaded suture anchors with suture eyelets are inserted at the articular margin of the greater tuberosity. A retrograde suture-passing instrument penetrates the rotator cuff to retrieve the sutures through the modified Neviaser or subclavian portal. An ipsilateral pair of suture eyelets in the suture anchor is passed through the margins of the rotator cuff tear. The blue suture of the second and third pair is pulled out of the lateral cannula, and the threaded blue suture of the third pair in the needle is passed through the blue suture of the second pair. After retrieving the blue suture of the first pair through the anterior portal, it is pulled out to pass the blue suture of the third pair through the eyelet of the anteromedial anchor. The blue suture is linked between two anchors. The medial row of suture-bridge is repaired with a sliding knot, and the sutures are not cut. Once the rotator cuff repair using the suture-bridge technique has been performed, the two blue strands in the anterior portal are tied. We describe our technique that possesses the advantages of both the double-pulley and suture-bridge techniques, which improves the pressurized contact area and maximizes compression along the medial row.

Mesh:

Year:  2007        PMID: 18058114     DOI: 10.1007/s00402-007-0527-0

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0936-8051            Impact factor:   3.067


  6 in total

Review 1.  Single versus double-row repair of the rotator cuff: does double-row repair with improved anatomical and biomechanical characteristics lead to better clinical outcome?

Authors:  Stephan Pauly; Christian Gerhardt; Jianhai Chen; Markus Scheibel
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-08-25       Impact factor: 4.342

2.  Revision of a pull-out suture anchor in the lateral row during the suture-bridge technique: technical note.

Authors:  Kyung-Cheon Kim; Kwang-Jin Rhee; Hyun-Dae Shin
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-03-05       Impact factor: 4.342

3.  The Combined "Double-Pulley" Simple Knot Technique for Arthroscopic Transtendon Fixation of Partial Articular-Sided Tear of the Subscapularis Tendon.

Authors:  Nata Parnes; Paul Carey; Mario Ciani; Monica Morman
Journal:  Arthrosc Tech       Date:  2016-02-22

4.  Double row equivalent for rotator cuff repair: A biomechanical analysis of a new technique.

Authors:  Sean Robinson; Henry Krigbaum; Jon Kramer; Connor Purviance; Robin Parrish; Joseph Donahue
Journal:  J Orthop       Date:  2018-03-21

5.  Linked Double-Row Equivalent Arthroscopic Rotator Cuff Repair Leads to Significantly Improved Patient Outcomes.

Authors:  Atsushi Endo; Paul Hoogervorst; Conrad Safranek; Kyle R Sochacki; Marc R Safran; Seth L Sherman; Joseph Donahue
Journal:  Orthop J Sports Med       Date:  2020-07-16

6.  Biomechanics of an interlinked suture anchor rotator cuff repair in a human cadaveric model.

Authors:  Klevis Aliaj; Heath B Henninger; Jean-Olivier E Tétreault-Paquin; Mark H Getelman; Joseph P Donahue
Journal:  JSES Open Access       Date:  2019-04-26
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.