Literature DB >> 18055793

Slit lamp-simulated oblique flashlight test in the detection of narrow angles in Chinese eyes: the Liwan eye study.

Mingguang He1, Wenyong Huang, David S Friedman, Changfan Wu, Yingfeng Zheng, Paul J Foster.   

Abstract

PURPOSE: To assess a modified slit lamp-simulated oblique flashlight test in the identification of persons with suspected angle closure.
METHODS: Standard oblique flashlight test (SOFT) and a modified slit lamp-simulated flashlight test (SSFT) were performed on participants identified as primary angle closure suspects and controls from a population-based study. SOFT graded the iris shadow on the nasal iris as shallow, medium, and deep. SSFT measured the length of iris shadow and corneal diameter by a slit lamp graticule eyepiece after standardizing the illumination parallel to the iris plane.
RESULTS: SOFT yielded sensitivity and specificity of 76.3% and 80.7% for the detection of eyes with two or more quadrants of pigmented trabecular meshwork not observed on static gonioscopy. Proportions of subjects in the "shallow" category increased from 9.6% in Shaffer angle width grade 4 to 82.3% in grade 0 and were 72.1% in those with steep, 56.7% in those with plateau, and 13.9% in those with regular iris profiles. SSFT yielded 84.8% sensitivity and 76.7% specificity using a cutoff of 0.18 for the ratio between iris shadow length and corneal diameter. This ratio was monotonically associated with the axial anterior chamber depth, and it was significantly greater in eyes with Shaffer angle width grade lower than 2 and significantly less in eyes with Shaffer angle width grades 3 and 4. Reproducibility of SSFT was high (paired t-test; P > 0.05).
CONCLUSIONS: More accurate measurement by controlling illumination and following a more precise method to measure shadow formation may improve the performance characteristics of this test. However, this method does not appear appropriate for community-based screening because of its relatively low specificity.

Entities:  

Mesh:

Year:  2007        PMID: 18055793     DOI: 10.1167/iovs.07-0670

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  11 in total

1.  Ability of non-ophthalmologist doctors to detect eyes with occludable angles using the flashlight test.

Authors:  Carolina Pelegrini Barbosa Gracitelli; Bruno Landgren; Flávia Bracale Graciani; Aline Kátia Siqueira Sousa; Augusto Paranhos; Tiago Santos Prata
Journal:  Int Ophthalmol       Date:  2013-10-01       Impact factor: 2.031

Review 2.  [Diacaustic examination of the iridocorneal angle : Video article].

Authors:  Andriy Zhuravlyov
Journal:  Ophthalmologe       Date:  2018-07       Impact factor: 1.059

3.  Five-year incidence of angle closure among glaucoma health examination participants.

Authors:  Kenji Kashiwagi; Tatsuya Chiba; Fumihiko Mabuchi; Toshie Furuya; Shigeo Tsukahara
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2012-10-25       Impact factor: 3.117

4.  Oblique Flashlight Test: Lighting Up Acute Angle-Closure Glaucoma.

Authors:  Kiyoshi Shikino; Yuta Hirose; Masatomi Ikusaka
Journal:  J Gen Intern Med       Date:  2016-05-12       Impact factor: 5.128

5.  Characterizing Current Attitudes and Practices for Human Subject Safety in Studies Involving Pupil Dilation.

Authors:  Jacob Szpernal; Joseph Carroll; Ryan Spellecy; Jane A Bachman Groth
Journal:  J Empir Res Hum Res Ethics       Date:  2020-11-02       Impact factor: 1.742

6.  Piloting targeted glaucoma screening: experiences of eye care services in Ganjam district, Odisha state, India.

Authors:  Sandeep Buttan; Ben Gascoyne; Sudeep Das; Elena Schmidt
Journal:  Int Health       Date:  2022-04-06       Impact factor: 3.131

7.  Pupillary Dilation in Research: More than Meets the Eye.

Authors:  Jacob Szpernal; Jane A Bachman Groth; Niamh Wynne; Vesper Williams; Ryan Spellecy; Catherine Thuruthumaly; Joseph Carroll
Journal:  Curr Eye Res       Date:  2022-05-02       Impact factor: 2.555

8.  Non-contact tests for identifying people at risk of primary angle closure glaucoma.

Authors:  Anish Jindal; Irene Ctori; Gianni Virgili; Ersilia Lucenteforte; John G Lawrenson
Journal:  Cochrane Database Syst Rev       Date:  2020-05-28

Review 9.  Community care for diabetic retinopathy and glaucoma in India: A panel discussion.

Authors:  Padmaja Kumari Rani; Vinay Nangia; Krishna R Murthy; Rohit C Khanna; Taraprasad Das
Journal:  Indian J Ophthalmol       Date:  2018-07       Impact factor: 1.848

10.  Exploring the Occurrence Mechanisms of Acute Primary Angle Closure by Comparative Analysis of Ultrasound Biomicroscopic Data of the Attack and Fellow Eyes.

Authors:  Fenglei Wang; Dabo Wang; Ling Wang
Journal:  Biomed Res Int       Date:  2020-04-24       Impact factor: 3.411

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.