Influence of the signal-to-noise ratio on the accuracy of IOLMaster measurements.

Chikako Suto1, Chiaki Sato, Emiko Shimamura, Hiroshi Toshida, Kazuo Ichikawa, Sadao Hori.   

Abstract

PURPOSE: To evaluate the relationship between the sound-to-noise ratio (SNR) and the reliability of axial length (AL) measurements obtained with the IOLMaster (Carl Zeiss Meditec AG).
SETTING: Department of Ophthalmology, Saiseikai Kurihashi Hospital, Saitama, Japan.
METHODS: In a clinical prospective study, 216 consecutive eyes of 144 patients scheduled for cataract surgery were evaluated for the type and severity of cataract using the Lens Opacities Classification System III. Preoperative and postoperative AL measurements were performed with the IOLMaster. The preoperative SNR values were used to divide the eyes into 5 groups. The following were compared between the groups: preoperative logMAR best spectacle-corrected visual acuity (BSCVA), difference in AL between preoperatively and postoperatively, error in the postoperative predicted refraction, and type and severity of cataract.
RESULTS: The preoperative logMAR BSCVA was significantly worse in eyes with an SNR <2 (P<.05). The AL was longer preoperatively than postoperatively in all groups, and there was a significant difference in the <2 SNR group and the 2 to <5 group (P<.05). There were no significant differences in the error in postoperative predicted refraction. The percentage of patients with P4 or worse posterior subcapsular cataract (PSC) increased significantly with a decrease in the SNR (P<.01). However, there was no correlation between nuclear color grade and the SNR.
CONCLUSION: The SNR value was useful in confirming the good quality of AL readings taken with the IOLMaster, even though the SNR value correlated significantly with the preoperative logMAR BSCVA and PSC severity.

Entities:  

Mesh:

Year:  2007        PMID: 18053905     DOI: 10.1016/j.jcrs.2007.07.031

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  5 in total

1.  Agreement of IOL power and axial length obtained by IOLMaster 500 vs IOLMaster 500 with Sonolink connection.

Authors:  Sabong Srivannaboon; Chareenun Chirapapaisan; Patchara Nantasri; Mathinee Chongchareon; Pratuangsri Chonpimai
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2013-01-12       Impact factor: 3.117

2.  Axial Length Measurement Failure Rates with the IOLMaster and Lenstar LS 900 in Eyes with Cataract.

Authors:  Colm McAlinden; Qinmei Wang; Konrad Pesudovs; Xin Yang; Fangjun Bao; Ayong Yu; Shishi Lin; Yifan Feng; Jinhai Huang
Journal:  PLoS One       Date:  2015-06-10       Impact factor: 3.240

3.  Ocular biometric characteristics of cataract patients in western China.

Authors:  Qing Huang; Yongzhi Huang; Qu Luo; Wei Fan
Journal:  BMC Ophthalmol       Date:  2018-04-17       Impact factor: 2.209

4.  Intraocular lens power calculation for plus and minus lenses in high myopia using partial coherence interferometry.

Authors:  Matthias Fuest; Niklas Plange; David Kuerten; Hannah Schellhase; Babac A E Mazinani; Peter Walter; Stephan Kohnen; Randolf A Widder; Gernot Roessler
Journal:  Int Ophthalmol       Date:  2021-02-01       Impact factor: 2.031

5.  Refractive predictability of partial coherence interferometry and factors that can affect it.

Authors:  Seung Mo Kim; Joohyun Choi; Sangkyung Choi
Journal:  Korean J Ophthalmol       Date:  2009-03-09
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.