Stent-graft deployment to treat a perigraft seroma formed after descending thoracic aortic surgery.

Hiroshi Ohtake1, Keiichi Kimura, Singo Soga, Junichirou Sanada, Osamu Matsui, Go Watanabe.   

Abstract

PURPOSE: To report a case of stent-graft implantation for a perigraft seroma that formed after descending thoracic aortic surgery. CASE REPORT: A 70-year-old woman presented with a perigraft seroma after a descending thoracic aortic surgery 10 years ago in which a polytetrafluoroethylene graft was used. Chest radiography and computed tomography confirmed the presence of a large perigraft seroma. The previous graft was covered with a stent-graft to decrease graft porosity. At 1 year, postoperative examinations revealed a decrease in the size of the perigraft seroma.
CONCLUSION: Stent-graft implantation could prove useful in cases of perigraft seromas where additional conventional surgery may pose difficulties.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 18052588     DOI: 10.1583/06-2037.1

Source DB:  PubMed          Journal:  J Endovasc Ther        ISSN: 1526-6028            Impact factor:   3.487


  3 in total

1.  Bailout Solution for Hemostasis from Distal Anastomotic Site during Total Aortic Arch Repair.

Authors:  Takashi Yamauchi
Journal:  Ann Thorac Cardiovasc Surg       Date:  2021-12-16       Impact factor: 1.889

2.  Mediastinal Perigraft Seroma after Repair of Type A Dissection with a Polyester Graft.

Authors:  Takashi Yamauchi; Suguru Kubota; Kosei Hagawa; Akira Suzuki
Journal:  Ann Vasc Dis       Date:  2017-03-31

3.  Expanding perigraft seroma after ascending aorta replacement.

Authors:  Shinji Kanemitsu; Shunsuke Sakamoto; Satoshi Teranishi; Toru Mizumoto
Journal:  J Cardiothorac Surg       Date:  2022-10-04       Impact factor: 1.522

  3 in total