Literature DB >> 18051089

Improved statistical TRE model when using a reference frame.

Andrew D Wiles1, Terry M Peters.   

Abstract

Target registration error (TRE) refers to the uncertainty in localizing a point of interest after a point-based registration is performed. Common in medical image registration, the metric is typically represented as a root-mean-square statistic. In the late 1990s, a statistical model was developed based on the rigid body definition of the fiducial markers and the localization error associated in measuring the fiducials. The statistical model assumed that the fiducial localizer error was isotropic, but recently the model was reworked to handle anisotropic fiducial localizer error (FLE). In image guided surgery, the statistical model is used to predict the surgical tool tip tracking accuracy associated with optical spatial measurement systems for which anisotropic FLE models are required. However, optical tracking systems often track the surgical tools relative to a patient based reference tool. Here the formulation for modeling the TRE of a surgical probe relative to a reference frame is developed mathematically and evaluated using a Monte Carlo simulation. The effectiveness of the statistical model is directly related to the FLE model, the fiducial marker design and the distance from centroid to target.

Entities:  

Mesh:

Year:  2007        PMID: 18051089     DOI: 10.1007/978-3-540-75757-3_54

Source DB:  PubMed          Journal:  Med Image Comput Comput Assist Interv


  4 in total

1.  Automatic image-to-world registration based on x-ray projections in cone-beam CT-guided interventions.

Authors:  N M Hamming; M J Daly; J C Irish; J H Siewerdsen
Journal:  Med Phys       Date:  2009-05       Impact factor: 4.071

2.  Localization and registration accuracy in image guided neurosurgery: a clinical study.

Authors:  Reuben R Shamir; Leo Joskowicz; Sergey Spektor; Yigal Shoshan
Journal:  Int J Comput Assist Radiol Surg       Date:  2008-10-28       Impact factor: 2.924

3.  Estimation of surgical tool-tip tracking error distribution in coordinate reference frame involving pivot calibration uncertainty.

Authors:  Zhe Min; Hongliang Ren; Max Q-H Meng
Journal:  Healthc Technol Lett       Date:  2017-09-18

4.  Quantitative error analysis for computer assisted navigation: a feasibility study.

Authors:  Ö Güler; M Perwög; F Kral; F Schwarm; Z R Bárdosi; G Göbel; W Freysinger
Journal:  Med Phys       Date:  2013-02       Impact factor: 4.071

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.