OBJECTIVE: To evaluate the AngioSculpt (ASC), a novel scoring balloon catheter designed to treat complex diffuse fibro-calcific atherosclerotic lesions and avoid device slippage during deployment, in patients with infra-popliteal disease. METHODS: The ASC incorporates a flexible nitinol scoring element containing three or more spiral struts which encircle a minimally compliant balloon to create focal concentration of the dilating force. Patients scheduled for percutaneous intervention of infra-popliteal arteries or planned amputation and with a reference vessel diameter of 1.5-3.5 mm were included in the study. RESULTS: A total of 42 patients and 56 lesions were treated at five sites. Of these, 38 patients (90.5%) presented with critical limb ischemia (Rutherford Class > or = 4). The ASC was successfully deployed in 98.2% (55/56) of lesions attempted and was used as primary therapy without stenting in 89.3% (50/56). Lesion morphology was complex, including moderate/severe calcification in 73%, lesion length 33.9 +/- 42.2 mm, bifurcation in 26.8%, and ostial in 12.5%. There was no significant device slippage and no perforations. Post-ASC dissections occurred in only six (10.7%) lesions and were minor or resolved with stenting. In 13 patients initially referred for amputation, ASC treatment resulted in limb salvage. CONCLUSIONS: The ASC is highly effective in a broad range of complex lesion morphologies, in most cases as stand-alone therapy, is associated with a very low complication rate and avoids device slippage during deployment. Additional studies are planned to assess the long term efficacy of this promising new technology. Copyright 2007 Wiley-Liss, Inc.
OBJECTIVE: To evaluate the AngioSculpt (ASC), a novel scoring balloon catheter designed to treat complex diffuse fibro-calcific atherosclerotic lesions and avoid device slippage during deployment, in patients with infra-popliteal disease. METHODS: The ASC incorporates a flexible nitinol scoring element containing three or more spiral struts which encircle a minimally compliant balloon to create focal concentration of the dilating force. Patients scheduled for percutaneous intervention of infra-popliteal arteries or planned amputation and with a reference vessel diameter of 1.5-3.5 mm were included in the study. RESULTS: A total of 42 patients and 56 lesions were treated at five sites. Of these, 38 patients (90.5%) presented with critical limb ischemia (Rutherford Class > or = 4). The ASC was successfully deployed in 98.2% (55/56) of lesions attempted and was used as primary therapy without stenting in 89.3% (50/56). Lesion morphology was complex, including moderate/severe calcification in 73%, lesion length 33.9 +/- 42.2 mm, bifurcation in 26.8%, and ostial in 12.5%. There was no significant device slippage and no perforations. Post-ASC dissections occurred in only six (10.7%) lesions and were minor or resolved with stenting. In 13 patients initially referred for amputation, ASC treatment resulted in limb salvage. CONCLUSIONS: The ASC is highly effective in a broad range of complex lesion morphologies, in most cases as stand-alone therapy, is associated with a very low complication rate and avoids device slippage during deployment. Additional studies are planned to assess the long term efficacy of this promising new technology. Copyright 2007 Wiley-Liss, Inc.
Authors: Grant C Sorkin; Travis M Dumont; Jorge L Eller; Maxim Mokin; L Nelson Hopkins; Kenneth V Snyder; Adnan H Siddiqui; Elad I Levy Journal: J Vasc Interv Neurol Date: 2014-05
Authors: Robert F Bonvini; Aljoscha Rastan; Sebastian Sixt; Marc Righini; Roland Hofstetter; Thomas Zeller Journal: Heart Vessels Date: 2009-11-22 Impact factor: 2.037
Authors: Mariya Kronlage; Carolin Werner; Matthias Dufner; Erwin Blessing; Oliver J Müller; Britta Heilmeier; Hugo A Katus; Christian Erbel Journal: Clin Res Cardiol Date: 2020-02-08 Impact factor: 5.460