Computed tomography phantom for radiochromic film dosimetry.

R Gotanda1, T Katsuda, T Gotanda, M Eguchi, S Takewa, A Tabuchi, H Yatake.   

Abstract

To evaluate in detail the dose distribution during computed tomography (CT), a sheet roll CT dosimetry phantom (SRCT-P) with a radiochromic film (RF) was experimentally developed. The SRCT-P was made by rolling up a vinyl chloride sheet in a cylindrical shape to arbitrarily select the SRCT-P diameter, dose measurement position, and depth. The SRCT-P centre core consisted of a plastic hose in which a 10 mm acrylic bar with a RF was inserted. To determine the availability of the SRCT-P, the surface and centre doses (at a 5 mm radius) at each SRCT-P diameter (6-16 cm; every 2 cm) were measured. The ratios of the centre-to-surface doses (D(centre)/D(surface)) systematically increased, from 80 to 111%, for decreasing SRCT-P diameters, between 16 and 6 cm, respectively. The centre dose approached the surface dose as the SRCT-P diameter decreased. To use a RF for a CT dose measurement, further detailed research and analysis is necessary. However, this study has shown that a SRCT-P is useful and beneficial for the measurement of the dose distribution during a CT examination.

Entities:  

Mesh:

Year:  2007        PMID: 18044303     DOI: 10.1007/bf03178426

Source DB:  PubMed          Journal:  Australas Phys Eng Sci Med        ISSN: 0158-9938            Impact factor:   1.430


  5 in total

1.  Ultraviolet exposure of Gafchromic XR-RV3 and XR-SP2 films.

Authors:  Toshizo Katsuda; Rumi Gotanda; Tatsuhiro Gotanda; Takuya Akagawa; Nobuyoshi Tanki; Tadao Kuwano; Kouichi Yabunaka
Journal:  J Appl Clin Med Phys       Date:  2015-09-08       Impact factor: 2.102

2.  Intensities of Incident and Transmitted Ultraviolet-A Rays through Gafchromic Films.

Authors:  Toshizo Katsuda; Rumi Gotanda; Tatsuhiro Gotanda; Takuya Akagawa; Nobuyoshi Tanki; Tadao Kuwano; Atsushi Noguchi; Kouichi Yabunaka
Journal:  J Med Phys       Date:  2017 Apr-Jun

3.  Simplified method for creating a density-absorbed dose calibration curve for the low dose range from Gafchromic EBT3 film.

Authors:  Tatsuhiro Gotanda; Toshizo Katsuda; Rumi Gotanda; Tadao Kuwano; Takuya Akagawa; Nobuyoshi Tanki; Akihiko Tabuchi; Tetsunori Shimono; Yasuyuki Kawaji
Journal:  J Med Phys       Date:  2016 Oct-Dec

4.  Correction of nonuniformity error of Gafchromic EBT2 and EBT3.

Authors:  Toshizo Katsuda; Rumi Gotanda; Tatsuhiro Gotanda; Takuya Akagawa; Nobuyoshi Tanki; Tadao Kuwano; Kouichi Yabunaka
Journal:  J Appl Clin Med Phys       Date:  2016-05-08       Impact factor: 2.102

5.  Comparing three UV wavelengths for pre-exposing Gafchromic EBT2 and EBT3 films.

Authors:  Toshizo Katsuda; Rumi Gotanda; Tatsuhiro Gotanda; Takuya Akagawa; Nobuyoshi Tanki; Tadao Kuwano; Kouichi Yabunaka
Journal:  J Appl Clin Med Phys       Date:  2015-11-08       Impact factor: 2.102

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.