Literature DB >> 18043166

Pulsatile versus nonpulsatile flow to maintain the equivalent coronary blood flow in the fibrillating heart.

Jae Seung Jung1, Ho Sung Son, Choon Hak Lim, Kyung Sun.   

Abstract

How much flow is required by a nonpulsatile pump to match the coronary blood flow equivalent to that of pulsatile pump? A cardiopulmonary bypass circuit from the right atrium to the ascending aorta was constructed in a ventricular fibrillation model using 13 Yorkshire swine. The animals were randomly divided into two groups: CONTROL (pulsatile T-PLS, n = 7) or EXPERIMENTAL (nonpulsatile Biopump, n = 6). The hemodynamic data at mid-LAD level was measured with a flow meter at baseline and every 20 minutes after pump flow initiation. The pump flow was started from 2 L/min in both groups (67 +/- 8 in CONTROL and 70 +/- 9 ml/kg/min in EXPERIMENTAL; p = NS), and the pump flow of the EXPERIMENTAL group was increased to match the coronary flow of the CONTROL group. To maintain mean velocity and flow in the LAD, the EXPERIMENTAL group required significantly higher pump flow at 20, 40, and 60 minutes (84 +/- 17 vs. 67 +/- 8, 87 +/- 24 vs. 67 +/- 8, 85 +/- 18 vs. 67 +/- 8 ml/kg/min, respectively, p < 0.05). The LAD diameter was substantially smaller in the CONTROL group and the resistance index was significantly lower in the CONTROL group at 80 minutes and 120 minutes after bypass (0.56 +/- 0.26 vs. 0.87 +/- 0.20 and 0.61 +/- 0.23 vs. 0.90 +/- 0.06; p < 0.05). In conclusion, we found that the nonpulsatile pump may require 25%-28% higher pump flow than the pulsatile pump to maintain equivalent coronary blood flow.

Entities:  

Mesh:

Year:  2007        PMID: 18043166     DOI: 10.1097/MAT.0b013e31815b2d00

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   2.872


  5 in total

1.  International conference on pediatric mechanical circulatory support systems and pediatric cardiopulmonary perfusion: outcomes and future directions.

Authors:  Akif Undar
Journal:  ASAIO J       Date:  2008 Mar-Apr       Impact factor: 2.872

2.  Studies of isolated global brain ischaemia: III. Influence of pulsatile flow during cerebral perfusion and its link to consistent full neurological recovery with controlled reperfusion following 30 min of global brain ischaemia.

Authors:  Bradley S Allen; Yoshihiro Ko; Gerald D Buckberg; Zhong Tan
Journal:  Eur J Cardiothorac Surg       Date:  2012-03-20       Impact factor: 4.191

3.  Change in myocardial oxygen consumption employing continuous-flow LVAD with cardiac beat synchronizing system, in acute ischemic heart failure models.

Authors:  Akihide Umeki; Takashi Nishimura; Yoshiaki Takewa; Masahiko Ando; Mamoru Arakawa; Yuichiro Kishimoto; Tomonori Tsukiya; Toshihide Mizuno; Shunei Kyo; Minoru Ono; Yoshiyuki Taenaka; Eisuke Tatsumi
Journal:  J Artif Organs       Date:  2013-01-17       Impact factor: 1.731

4.  Coronary versus carotid blood flow and coronary perfusion pressure in a pig model of prolonged cardiac arrest treated by different modes of venoarterial ECMO and intraaortic balloon counterpulsation.

Authors:  Jan Bělohlávek; Mikuláš Mlček; Michal Huptych; Tomáš Svoboda; Stěpán Havránek; Petr Ošt'ádal; Tomáš Bouček; Tomáš Kovárník; František Mlejnský; Vratislav Mrázek; Marek Bělohlávek; Michael Aschermann; Aleš Linhart; Otomar Kittnar
Journal:  Crit Care       Date:  2012-12-12       Impact factor: 9.097

5.  Comparison of Hemodynamic Energy between Expanded Polytetrafluoroethylene and Dacron Artificial Vessels.

Authors:  Jaekwan Lim; Jong Yun Won; Chi Bum Ahn; Jieon Kim; Hee Jung Kim; Jae Seung Jung
Journal:  J Chest Surg       Date:  2021-04-05
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.