The Cleveland Clinic PediPump: anatomic modeling and virtual fitting studies in a lamb model.

Angela M Noecker1, Faruk Cingoz, Yoshio Ootaki, Jenny Liu, Stacie Kuzmiak, Mike W Kopcak, Kiyotaka Fukamachi, Brian W Duncan.   

Abstract

Implantation of ventricular assist devices (VADs) is challenging in small patients with limited space in the chest. We created three-dimensional models of lambs to facilitate fitting of the PediPump, a pediatric VAD currently under development. Serial computed tomography (CT) scans were acquired at multiple time points (n = 8) for three lambs. Digital models were created using these CT datasets and three-dimensional image processing software (Mimics, Materialise). Pixels representing the heart and chest wall were rendered as three-dimensional models. Using three-dimensional model manipulation software (Magics RP, Materialise), on-screen models of extravascular and intravascular VADs were placed in right, left and biventricular support configurations to determine optimal placement. A cannulation strategy was established and in some cases three-dimensional models of the inflow and outflow grafts were created. After the final CT study, an open-chest fitting study was performed using rapid prototype models of the pediatric VAD and cannulas. The pump location and orientation predictions from the virtual fitting studies matched those determined at the time of the open-chest fitting studies. Using three-dimensional modeling, we have established a fitting protocol that facilitates animal implantations; the same modeling techniques may be useful for device fitting in humans.

Entities:  

Mesh:

Year:  2007        PMID: 18043154     DOI: 10.1097/MAT.0b013e31805fe98b

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   2.872


  3 in total

1.  The national heart, lung, and blood institute pediatric circulatory support program: a summary of the 5-year experience.

Authors:  J Timothy Baldwin; Harvey S Borovetz; Brian W Duncan; Mark J Gartner; Robert K Jarvik; William J Weiss
Journal:  Circulation       Date:  2011-03-22       Impact factor: 29.690

2.  International conference on pediatric mechanical circulatory support systems and pediatric cardiopulmonary perfusion: outcomes and future directions.

Authors:  Akif Undar
Journal:  ASAIO J       Date:  2008 Mar-Apr       Impact factor: 2.872

3.  Human Fitting Studies of Cleveland Clinic Continuous-Flow Total Artificial Heart.

Authors:  Jamshid H Karimov; Robert J Steffen; Nicole Byram; Gengo Sunagawa; David Horvath; Vincent Cruz; Leonard A R Golding; Kiyotaka Fukamachi; Nader Moazami
Journal:  ASAIO J       Date:  2015 Jul-Aug       Impact factor: 2.872

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.