Literature DB >> 18043061

Quantification of epileptiform electroencephalographic activity during sevoflurane mask induction.

Mika O K Särkelä1, Miikka J Ermes, Mark J van Gils, Arvi M Yli-Hankala, Ville H Jäntti, Anne P Vakkuri.   

Abstract

BACKGROUND: Sevoflurane may induce epileptiform electroencephalographic activity leading to unstable Bispectral Index numbers, underestimating the hypnotic depth of anesthesia. The authors developed a method for the quantification of epileptiform electroencephalographic activity during sevoflurane anesthesia.
METHODS: Electroencephalographic data from 60 patients under sevoflurane mask induction were used in the analysis. Electroencephalographic data were visually classified. A novel electroencephalogram-derived quantity, wavelet subband entropy (WSE), was developed. WSE variables were calculated from different frequency bands. Performance of the WSE in detection and quantification of epileptiform electroencephalographic activity and the ability of the WSE to recognize misleading Bispectral Index readings caused by epileptiform activity were evaluated.
RESULTS: Two WSE variables were found to be sufficient for the quantification of epileptiform activity: WSE from the frequency bands 4-16 and 16-32 Hz. The lower frequency band was used for monophasic pattern monitoring, and the higher frequency band was used for spike activity monitoring. WSE values of the lower and higher bands followed the time evolution of epileptiform activity with prediction probabilities of 0.809 (SE, 0.007) and 0.804 (SE, 0.007), respectively. In deep anesthesia with epileptiform activity, WSE detected electroencephalographic patterns causing Bispectral Index readings greater than 60, with event sensitivity of 97.1%.
CONCLUSIONS: The developed method proved useful in detection and quantification of epileptiform electroencephalographic activity during sevoflurane anesthesia. In the future, it may improve the understanding of electroencephalogram-derived information by assisting in recognizing misleading readings of depth-of-anesthesia monitors. The method also may assist in minimizing the occurrence of epileptiform activity and seizures during sevoflurane anesthesia.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 18043061     DOI: 10.1097/01.anes.0000291444.68894.ee

Source DB:  PubMed          Journal:  Anesthesiology        ISSN: 0003-3022            Impact factor:   7.892


  6 in total

Review 1.  Prognostic Value of EEG in Patients after Cardiac Arrest-An Updated Review.

Authors:  Wolfgang Muhlhofer; Jerzy P Szaflarski
Journal:  Curr Neurol Neurosci Rep       Date:  2018-03-10       Impact factor: 5.081

2.  Recent advances in pediatric anesthesia.

Authors:  Josef Holzki
Journal:  Korean J Anesthesiol       Date:  2011-05-31

Review 3.  Quantitative measures of EEG for prediction of outcome in cardiac arrest subjects treated with hypothermia: a literature review.

Authors:  Shadnaz Asgari; Hana Moshirvaziri; Fabien Scalzo; Nima Ramezan-Arab
Journal:  J Clin Monit Comput       Date:  2018-02-26       Impact factor: 2.502

4.  EEG entropy measures in anesthesia.

Authors:  Zhenhu Liang; Yinghua Wang; Xue Sun; Duan Li; Logan J Voss; Jamie W Sleigh; Satoshi Hagihira; Xiaoli Li
Journal:  Front Comput Neurosci       Date:  2015-02-18       Impact factor: 2.380

5.  A Comparison of Multiscale Permutation Entropy Measures in On-Line Depth of Anesthesia Monitoring.

Authors:  Cui Su; Zhenhu Liang; Xiaoli Li; Duan Li; Yongwang Li; Mauro Ursino
Journal:  PLoS One       Date:  2016-10-10       Impact factor: 3.240

6.  Spurious electroencephalographic activity due to pulsation artifact in the depth of anesthesia monitor.

Authors:  Kotoe Kamata; Tarmo Lipping; Arvi Yli-Hankala; Ville Jäntti; Masanori Yamauchi
Journal:  JA Clin Rep       Date:  2021-04-17
  6 in total