Literature DB >> 18041805

Relationships between MR transverse relaxation parameters R*(2), R(2) and R'(2) and hepatic iron content in thalassemic mice at 1.5 T and 3 T.

Ruitian Song1, Wei Lin, Qiukan Chen, Toshio Asakura, Felix W Wehrli, Hee Kwon Song.   

Abstract

Assessment of hepatic iron concentration is important in the management of patients with thalassemia. The goal of this study was to investigate the relationships between the three MR transverse relaxation rates, R*(2), R(2) and R'(2), and hepatic iron content in a mouse model of thalassemia at 1.5 and 3 T field strengths. A GESFIDE (gradient-echo sampling of free induction decay and echo) pulse sequence was used to measure the three parameters efficiently in a single scan in a study examining the livers of normal and thalassemic mice, including a subgroup of the latter that were subjected to periodic transfusions. The results showed that R*(2), R(2) and R'(2) all correlated closely with liver iron concentration at both 1.5 T and 3 T, with correlation coefficients ranging from 0.72 to 0.79. High degrees of correlation (r = 0.93-0.99) were also observed among the three MR parameters at both field strengths. It can be concluded that the three rates could all be effective for assessing hepatic iron concentration and that imaging at higher fields may not offer any advantages over that at lower fields.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18041805     DOI: 10.1002/nbm.1227

Source DB:  PubMed          Journal:  NMR Biomed        ISSN: 0952-3480            Impact factor:   4.044


  3 in total

1.  Assessment of MR-based R2* and quantitative susceptibility mapping for the quantification of liver iron concentration in a mouse model at 7T.

Authors:  Gregory Simchick; Zhi Liu; Tamas Nagy; May Xiong; Qun Zhao
Journal:  Magn Reson Med       Date:  2018-03-25       Impact factor: 4.668

2.  Reduced transverse relaxation rate (RR2) for improved sensitivity in monitoring myocardial iron in thalassemia.

Authors:  Jerry S Cheung; Wing-Yan Au; Shau-Yin Ha; Daniel Kim; Jens H Jensen; Iris Y Zhou; Matthew M Cheung; Yin Wu; Hua Guo; Pek-Lan Khong; Truman R Brown; Gary M Brittenham; Ed X Wu
Journal:  J Magn Reson Imaging       Date:  2011-06       Impact factor: 4.813

3.  GESFIDE-PROPELLER approach for simultaneous R2 and R2* measurements in the abdomen.

Authors:  Ning Jin; Yang Guo; Zhuoli Zhang; Longjiang Zhang; Guangming Lu; Andrew C Larson
Journal:  Magn Reson Imaging       Date:  2013-09-14       Impact factor: 2.546

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.