P O'Shea, M Kimmel, X Gu, R Trebino.
Abstract
We show that a frequency-resolved optical gating device using (1) a thick nonlinear crystal to replace the usual thin crystal and spectrometer and (2) a Fresnel biprism to replace the beam splitter and delay line yields a remarkably simple single-shot ultrashort-pulse intensity-and-phase measurement device with no sensitive alignment parameters and significantly greater sensitivity.Year: 2001 PMID: 18040496 DOI: 10.1364/ol.26.000932