This paper presents a method to provide electrical connection to a 2D capacitive micromachined ultrasonic transducer (CMUT) array. The interconnects are processed after the CMUTs are fabricated on the front side of a silicon wafer. Connections to array elements are made from the back side of the substrate via highly conductive silicon pillars that result from a deep reactive ion etching (DRIE) process. Flip-chip bonding is used to integrate the CMUT array with an integrated circuit (IC) that comprises the front-end circuits for the transducer and provides mechanical support for the trench-isolated array elements. Design, fabrication process and characterization results are presented. The advantages when compared to other through-wafer interconnect techniques are discussed.

Entities:  

Year:  2007        PMID: 18037982      PMCID: PMC2084216          DOI: 10.1016/j.sna.2007.04.008

Source DB:  PubMed          Journal:  Sens Actuators A Phys        ISSN: 0924-4247            Impact factor:   3.407


  2 in total

1.  Optimizing the beam pattern of a forward-viewing ring-annular ultrasound array for intravascular imaging.

Authors:  Yao Wang; Douglas N Stephens; Matthew O'Donnell
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2002-12       Impact factor: 2.725

2.  A miniaturized catheter 2-D array for real-time, 3-D intracardiac echocardiography.

Authors:  Warren Lee; Salim F Idriss; Patrick D Wolf; Stephen W Smith
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2004-10       Impact factor: 2.725

  2 in total
  4 in total

1.  Capacitive micromachined ultrasonic transducers for therapeutic ultrasound applications.

Authors:  Serena H Wong; Mario Kupnik; Ronald D Watkins; Kim Butts-Pauly; Butrus T Pierre Khuri-Yakub
Journal:  IEEE Trans Biomed Eng       Date:  2009-07-21       Impact factor: 4.538

2.  Fully Solution-Processable Fabrication of Multi-Layered Circuits on a Flexible Substrate Using Laser Processing.

Authors:  Seok Young Ji; Wonsuk Choi; Hoon-Young Kim; Jin-Woo Jeon; Sung-Hak Cho; Won Seok Chang
Journal:  Materials (Basel)       Date:  2018-02-09       Impact factor: 3.623

3.  Fabrication and Packaging of CMUT Using Low Temperature Co-Fired Ceramic.

Authors:  Fikret Yildiz; Tadao Matsunaga; Yoichi Haga
Journal:  Micromachines (Basel)       Date:  2018-10-27       Impact factor: 2.891

4.  An ultra-high element density pMUT array with low crosstalk for 3-D medical imaging.

Authors:  Yi Yang; He Tian; Yu-Feng Wang; Yi Shu; Chang-Jian Zhou; Hui Sun; Cang-Hai Zhang; Hao Chen; Tian-Ling Ren
Journal:  Sensors (Basel)       Date:  2013-07-26       Impact factor: 3.576

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.