Literature DB >> 18037793

Standardizing display conditions of diffusion-weighted images using concurrent b0 images: a multi-vendor multi-institutional study.

Makoto Sasaki1, Masahiro Ida, Kei Yamada, Yoshiyuki Watanabe, Mieko Matsui.   

Abstract

PURPOSE: To establish a practical method that uses concurrent b0 images to standardize the display conditions for diffusion-weighted images (DWI) that vary among institutions and interpreters.
METHOD: Using identical parameters, we obtained DWI for 12 healthy volunteers at 4 institutions using 4 MRI scanners from 3 vendors. Three operators manually set the window width for the images equal to the signal intensity of the normal-appearing thalamus on b0 images and set the window level at half and then exported the images to 8-bit gray-scale images. We calculated the mean pixel values of the brain objects in the images and examined the variation among scanners, operators, and subjects. RESULT: Following our method, the DWI of the 12 subjects obtained using the 4 different scanners had nearly identical contrast and brightness. The mean pixel values of the brain on the exported images among the operators and subjects were not significantly different, but we found a slight, significant difference among the scanners.
CONCLUSION: Determining DWI display conditions by using b0 images is a simple and practical method to standardize window width and level for evaluating diffusion abnormalities and decreasing variation among institutions and operators.

Mesh:

Year:  2007        PMID: 18037793     DOI: 10.2463/mrms.6.133

Source DB:  PubMed          Journal:  Magn Reson Med Sci        ISSN: 1347-3182            Impact factor:   2.471


  6 in total

1.  Methods for optimizing the display conditions of brain magnetic resonance images.

Authors:  Toshimasa Hara; Yusuke Inoue; Ryutaro Ukisu; Hirofumi Hata
Journal:  Jpn J Radiol       Date:  2017-07-20       Impact factor: 2.374

2.  Automated adjustment of display conditions in brain MR images: diffusion-weighted MRIs and apparent diffusion coefficient maps for hyperacute ischemic stroke.

Authors:  Hiroyuki Nagashima; Kunio Doi; Toshihiro Ogura; Hiroshi Fujita
Journal:  Radiol Phys Technol       Date:  2012-11-27

3.  PI-RADS version 2: quantitative analysis aids reliable interpretation of diffusion-weighted imaging for prostate cancer.

Authors:  Sung Yoon Park; Su-Jin Shin; Dae Chul Jung; Nam Hoon Cho; Young Deuk Choi; Koon Ho Rha; Sung Joon Hong; Young Taik Oh
Journal:  Eur Radiol       Date:  2016-12-12       Impact factor: 5.315

4.  Multicentre multiobserver study of diffusion-weighted and fluid-attenuated inversion recovery MRI for the diagnosis of sporadic Creutzfeldt-Jakob disease: a reliability and agreement study.

Authors:  Koji Fujita; Masafumi Harada; Makoto Sasaki; Tatsuhiko Yuasa; Kenji Sakai; Tsuyoshi Hamaguchi; Nobuo Sanjo; Yusei Shiga; Katsuya Satoh; Ryuichiro Atarashi; Susumu Shirabe; Ken Nagata; Tetsuya Maeda; Shigeo Murayama; Yuishin Izumi; Ryuji Kaji; Masahito Yamada; Hidehiro Mizusawa
Journal:  BMJ Open       Date:  2012-01-30       Impact factor: 2.692

5.  Guidelines for Intravenous Thrombolysis (Recombinant Tissue-type Plasminogen Activator), the Third Edition, March 2019: A Guideline from the Japan Stroke Society.

Authors:  Kazunori Toyoda; Masatoshi Koga; Yasuyuki Iguchi; Ryo Itabashi; Manabu Inoue; Yasushi Okada; Kuniaki Ogasawara; Akira Tsujino; Yasuhiro Hasegawa; Taketo Hatano; Hiroshi Yamagami; Toru Iwama; Yoshiaki Shiokawa; Yasuo Terayama; Kazuo Minematsu
Journal:  Neurol Med Chir (Tokyo)       Date:  2019-12-05       Impact factor: 1.742

6.  Quantitative Evaluation of Display Contrast of Gd-EOB-DTPA-Enhanced Magnetic Resonance Images: Effects of the Flip Angle and Grayscale Gamma Value.

Authors:  Yusuke Inoue; Hirofumi Hata; Ai Nakajima; Keiji Matsunaga; Yusuke Ohzeki; Tetsuya Hashimoto; Hiroki Haradome
Journal:  Radiol Res Pract       Date:  2019-01-16