Literature DB >> 18036428

Estimate of radiation dose to the lens in balloon sinuplasty.

Rakesh K Chandra1.   

Abstract

OBJECTIVES: To estimate radiation dose to the lens during fluoroscopy-assisted balloon dilation of sinus ostia and to estimate the length of fluoroscopy time that will be tolerated.
METHODS: Radiation dose to the lens per unit fluoroscopy time was extrapolated from published data in fluoroscopically-guided balloon dacrocystoplasty.
RESULTS: Mean exposure varies from 0.041 (right eye) to 0.284 (left eye) mGy/sec (P = 0.037) because the left eye is closer to the radiation source during the lateral projection. Threshold for lenticular opacity has been estimated as 500 mGy, which would be attained in the left eye after approximately 29 minutes of fluoroscopy.
CONCLUSIONS: The lens may tolerate <30 minutes of fluoroscopy during balloon sinuplasty. The left eye receives a potentially greater radiation dose because of its proximity to the source in the lateral projection. Dedicated studies are indicated to specifically examine this issue during balloon sinuplasty.

Entities:  

Mesh:

Year:  2007        PMID: 18036428     DOI: 10.1016/j.otohns.2007.09.002

Source DB:  PubMed          Journal:  Otolaryngol Head Neck Surg        ISSN: 0194-5998            Impact factor:   3.497


  4 in total

Review 1.  Comprehensive review on endonasal endoscopic sinus surgery.

Authors:  Rainer K Weber; Werner Hosemann
Journal:  GMS Curr Top Otorhinolaryngol Head Neck Surg       Date:  2015-12-22

Review 2.  Balloon sinuplasty: a current hot topic in rhinology.

Authors:  Jin Keat Siow; Basel Al Kadah; Jochen A Werner
Journal:  Eur Arch Otorhinolaryngol       Date:  2008-02-26       Impact factor: 2.503

Review 3.  Balloon sinuplasty versus surgical management of chronic rhinosinusitis.

Authors:  Alexander E Stewart; Winston C Vaughan
Journal:  Curr Allergy Asthma Rep       Date:  2010-05       Impact factor: 4.806

4.  [Update: catheter-based balloon dilatation of the sinuses without fluoroscopy. Dilation technique with an illumination system].

Authors:  D Brehmer
Journal:  HNO       Date:  2008-08       Impact factor: 1.284

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.