Literature DB >> 18031444

A 4-year prospective clinical and radiological study of maxillary dental implants supporting single-tooth crowns using early and delayed loading protocols.

Ilser Turkyilmaz1, Mehmet Avci, Serkan Kuran, Esma Nida Ozbek.   

Abstract

BACKGROUND: Recent studies have showed that immediate/early loading of dental implants is a clinically feasible concept with results similar to those for standard two-stage procedures, especially in the mandible. However, there are only a few studies regarding the immediate/early loading of maxillary implants supporting single-tooth crowns.
PURPOSE: The aim of this study was to compare the clinical and radiological outcomes of early- and delayed-loaded dental implants supporting single-tooth crowns in the maxilla.
MATERIALS AND METHODS: Twenty-nine patients were consecutively treated between 2000 and 2002 with 59 Brånemark System MK III TiUnite implants (Nobel Biocare AB, Göteborg, Sweden) in the maxilla. Two groups were formed according to the loading protocols. In the test group, definitive implant-supported single crowns were delivered to 19 patients 6 weeks after the implant placement. In the control group, definitive implant-supported single crowns were delivered to 10 patients 6 months after the implant placement. Clinical and radiographic parameters were recorded at baseline, 1 to 4 years. Implant stability measurements have only been performed at 4-year follow-up recall.
RESULTS: Overall, three implants were lost during the study period. Two implants were lost in the test group including 36 implants, which indicated a survival rate of 94.4%. One of the lost implants was replaced and then osseointegrated successfully. One implant was lost in the control group during the healing period, which indicated a survival rate of 95.7%. The average marginal bone loss was 1.11 mm for 56 implants after 4 years. There were no significant differences in marginal bone levels, insertion torque, and resonance frequency values between the two groups.
CONCLUSION: The results of this study indicate that 6 weeks of early loading period for TiUnite-surface titanium implants in the maxilla is reliable and predictable for this patient population and may offer an alternative to the standard loading protocol.

Entities:  

Mesh:

Year:  2007        PMID: 18031444     DOI: 10.1111/j.1708-8208.2007.00045.x

Source DB:  PubMed          Journal:  Clin Implant Dent Relat Res        ISSN: 1523-0899            Impact factor:   3.932


  6 in total

1.  Bone resorption and complications in alveolar distraction osteogenesis.

Authors:  Tobias Ettl; Till Gerlach; Thomas Schüsselbauer; Martin Gosau; Torsten E Reichert; Oliver Driemel
Journal:  Clin Oral Investig       Date:  2009-09-23       Impact factor: 3.573

2.  Oral Rehabilitation of a Severely Resorbed Edentulous Maxilla with Screwed-retained Hybrid Denture Using Cresco System: A Case Report.

Authors:  Ilser Turkyilmaz; Neal S Patel; Edwin A McGlumphy
Journal:  Eur J Dent       Date:  2008-07

3.  Marginal bone response of implants with platform switching and non-platform switching abutments in posterior healed sites: a 1-year prospective study.

Authors:  Yun-Chi Wang; Joseph Y K Kan; Kitichai Rungcharassaeng; Phillip Roe; Jaime L Lozada
Journal:  Clin Oral Implants Res       Date:  2014-01-03       Impact factor: 5.977

4.  Interimplant papilla reconstruction by using demineralized freeze dried bone allograft block fixed by titanium screw: a case report.

Authors:  Preeti Charde; M L Bhongade; Aniruddha Deshpande; Anendd Jadhav; Kaustubh Thakare; Priyanka Jaiswal
Journal:  Case Rep Dent       Date:  2012-12-10

5.  Interproximal Papillae Reconstruction around Implant Using Subepithelial Connective Tissue Graft in Maxillary Anterior Region: A Case Series.

Authors:  Satish Gupta; Vikas Deo; Cecil Williams
Journal:  J Oral Maxillofac Res       Date:  2012-07-01

6.  Clinical efficacy of early loading versus conventional loading of dental implants.

Authors:  Yanfei Zhu; Xinyi Zheng; Guanqi Zeng; Yi Xu; Xinhua Qu; Min Zhu; Eryi Lu
Journal:  Sci Rep       Date:  2015-11-06       Impact factor: 4.379

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.