Literature DB >> 18031294

A highly-sensitive plasma von Willebrand factor ristocetin cofactor (VWF:RCo) activity assay by flow cytometry.

D Chen1, C A Daigh, J I Hendricksen, R K Pruthi, W L Nichols, J A Heit, W G Owen.   

Abstract

BACKGROUND: Assays of plasma von Willebrand factor (VWF) ristocetin cofactor activity (VWF:RCo) are essential for the laboratory diagnosis of von Willebrand disease (VWD) and for monitoring therapy. However, current manual or automated VWF:RCo assay methods have relatively poor operating characteristics. Our goal was to develop and validate a simple, accurate, specific and sensitive platelet-based VWF:RCo assay.
METHODS: Using green or red fluorochrome-labeled, fixed normal platelets and normal or patient plasma, ristocetin-dependent and VWF-mediated platelet aggregation was detected by flow cytometry. VWF:RCo activity was assayed as the number of double-positive events (green and red) among all green or red events, relative to the calibrator plasma signal (6-150% or IU dL(-1)), and reported as percent or IU dL(-1). We tested plasma samples from normal donors (n = 51) and known VWD patients (type 1, n = 16; type 2, n = 17) based on clinical history, levels of plasma VWF antigen (VWF:Ag), VWF:RCo activity (manual platelet aggregometry/agglutination assay), factor (F) VIII activity and VWF multimer analysis.
RESULTS: For normal donors and type 1 VWD patients, VWF:RCo activity by flow cytometry vs. manual platelet aggregation correlated closely (R2 = 0.74), and VWF:RCo/VWF:Ag ratios did not differ significantly. In contrast, VWF:RCo/VWF:Ag ratios for type 2 VWD subtypes were significantly lower using VWF:RCo by flow cytometry vs. manual platelet aggregation assay (P < 0.01), especially for type 2A VWD patients.
CONCLUSIONS: This new flow cytometry-based VWF:RCo assay is simple, accurate, specific and sensitive, particularly for type 2 VWD.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 18031294     DOI: 10.1111/j.1538-7836.2007.02845.x

Source DB:  PubMed          Journal:  J Thromb Haemost        ISSN: 1538-7836            Impact factor:   5.824


  7 in total

Review 1.  Laboratory testing for von Willebrand disease: toward a mechanism-based classification.

Authors:  Richard Torres; Yuri Fedoriw
Journal:  Clin Lab Med       Date:  2009-06       Impact factor: 1.935

2.  Hypertrophic obstructive cardiomyopathy, acquired von Willebrand syndrome, and gastrointestinal bleeding.

Authors:  Rajiv K Pruthi
Journal:  Mayo Clin Proc       Date:  2011-03       Impact factor: 7.616

Review 3.  Diagnostic approach to von Willebrand disease.

Authors:  Christopher Ng; David G Motto; Jorge Di Paola
Journal:  Blood       Date:  2015-02-23       Impact factor: 22.113

Review 4.  Perils, problems, and progress in laboratory diagnosis of von Willebrand disease.

Authors:  Veronica H Flood
Journal:  Semin Thromb Hemost       Date:  2013-12-12       Impact factor: 4.180

Review 5.  Platelet-dependent von Willebrand factor activity. Nomenclature and methodology: communication from the SSC of the ISTH.

Authors:  I Bodó; J Eikenboom; R Montgomery; J Patzke; R Schneppenheim; J Di Paola
Journal:  J Thromb Haemost       Date:  2015-05-09       Impact factor: 5.824

6.  Hypertrophic obstructive cardiomyopathy, bleeding history, and acquired von Willebrand syndrome: response to septal myectomy.

Authors:  Joseph L Blackshear; Hartzell V Schaff; Steve R Ommen; Dong Chen; William L Nichols
Journal:  Mayo Clin Proc       Date:  2011-03       Impact factor: 7.616

7.  A Comparative Evaluation of an Automated Functional Assay for Von Willebrand Factor Activity in Type 1 Von Willebrand Disease.

Authors:  Shiue-Wei Lai; Chia-Yau Chang; Shin-Nan Cheng; Shu-Hsia Hu; Chung-Yu Lai; Yeu-Chin Chen
Journal:  Int J Gen Med       Date:  2021-09-02
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.